SUBCUTANEOUS, CATHETER-RELATED INFLAMMATION IN A RABBIT MODEL CORRELATES WITH PERIPHERAL VEIN PHLEBITIS IN HUMAN VOLUNTEERS

被引:12
作者
CARRUTH, WA
BYRON, MP
SOLOMON, DD
WHITE, WL
STODDARD, GJ
MAROSOK, RD
SHERERTZ, RJ
机构
[1] WAKE FOREST UNIV,SCH MED,DEPT MED,INFECT DIS SECT,WINSTON SALEM,NC 27157
[2] WAKE FOREST UNIV,SCH MED,DEPT PATHOL,WINSTON SALEM,NC 27157
[3] WAKE FOREST UNIV,SCH MED,DEPT DERMATOL,WINSTON SALEM,NC 27157
[4] BECTON DICKINSON VASC ACCESS,SANDY,UT
[5] BECTON DICKINSON PHARMACEUT SYST,PONT CLAIX,FRANCE
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1994年 / 28卷 / 02期
关键词
D O I
10.1002/jbm.820280217
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the development of a polyurethane vascular catheter with anti-infective properties, it became desirable to develop a measure of tissue inflammation. This was investigated in a rabbit model by implanting uncoated catheters and catheters coated with heparin (HEP), chlorhexidine (CH), or CH/HEP in the subcutaneous space with or without 10(4) Staphylococcus aureus. At intervals of 2, 4, and 7 days after implantation, animals were sacrificed; tissue blocks containing catheters were removed and preserved with formaldehyde; and sections were stained with hematoxylin and eosin. Using a histologic index, 240 sections (10 for each experimental condition) were evaluated by two investigators blinded to experimental conditions. Uncoated catheters or catheters coated with CH alone had a lower histologic index (less inflammation) than catheters coated with HEP alone or CH/HEP (P <.05). When catheters were inoculated with S. aureus, those coated with CH, with or without HEP, had a lower histologic index than uncoated catheters (P <.05). Next, 30 volunteers had a control catheter inserted in a vein in one forearm and a catheter coated with either CH alone or CH/HEP in a vein in the other forearm. After 96 h of observation there was a greater risk of phlebitis associated with CH/HEP catheters than control catheters (P <.05), and no difference in the risk of phlebitis between CH catheters and control catheters (P = 0.43). Thus, the amount of inflammation around the catheter in the subcutaneous space of rabbit correlated with the risk of peripheral vein phlebitis. (C) 1994 John Wiley and Sons, Inc.
引用
收藏
页码:259 / 267
页数:9
相关论文
共 39 条
[1]  
ADAMS SD, 1986, HEART LUNG, V15, P134
[2]  
CAIRO MS, 1983, AM J PATHOL, V113, P67
[3]   ALLERGIC REACTION TO CHLORHEXIDINE IN AN ANESTHETIZED PATIENT [J].
CHEUNG, J ;
OLEARY, JJ .
ANAESTHESIA AND INTENSIVE CARE, 1985, 13 (04) :429-439
[4]  
COLLIN J, 1975, LANCET, V2, P150
[5]   CHLORHEXIDINE RESISTANCE IN METHICILLIN-RESISTANT STAPHYLOCOCCUS-AUREUS OR JUST AN ELEVATED MIC - AN INVITRO AND INVIVO ASSESSMENT [J].
COOKSON, BD ;
BOLTON, MC ;
PLATT, JH .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1991, 35 (10) :1997-2002
[6]  
DAVID N, 1982, NITA, V5, P379
[7]  
FLOWERS RH, 1989, JAMA-J AM MED ASSOC, V261, P873
[8]   THE INFLUENCE OF CHLORHEXIDINE ON SUPEROXIDE GENERATION BY INDUCED HUMAN-NEUTROPHILS [J].
GABLER, WL ;
BULLOCK, WW ;
CREAMER, HR .
JOURNAL OF PERIODONTAL RESEARCH, 1987, 22 (06) :445-450
[9]   INFUSION THROMBOPHLEBITIS - A PROSPECTIVE COMPARISON OF 645 VIALON AND TEFLON CANNULAE IN ANESTHETIC AND POSTOPERATIVE USE [J].
GAUKROGER, PB ;
ROBERTS, JG ;
MANNERS, TA .
ANAESTHESIA AND INTENSIVE CARE, 1988, 16 (03) :265-271
[10]   COMPARISON OF 4-PERCENT CHLORHEXIDINE GLUCONATE IN A DETERGENT BASE (HIBICLENS) AND POVIDONE-IODINE (BETADINE) FOR THE SKIN PREPARATION OF HEMODIALYSIS-PATIENTS AND PERSONNEL [J].
GOLDBLUM, SE ;
ULRICH, JA ;
GOLDMAN, RS ;
REED, WP ;
AVASTHI, PS .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1983, 2 (05) :548-552