HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH POSTCOLUMN CHEMILUMINESCENCE DETECTION FOR SIMULTANEOUS DETERMINATION OF TRACE N-NITROSAMINES AND CORRESPONDING SECONDARY-AMINES IN GROUNDWATER

被引:17
作者
FU, CG
XU, HD
机构
关键词
HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY; CHEMILUMINESCENCE DETECTION; NITROSAMINES; SECONDARY AMINES; GROUNDWATER;
D O I
10.1039/an9952001147
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, selective and reliable high-performance liquid chromatographic method with chemiluminescence detection is described for the determination of trace N-nitrosamines and corresponding secondary amines simultaneously in environmental water samples. The method combines solid-phase extraction on to a mini activated carbon column, followed by elution with acetone and concentration of the extracts by denitrosation and fluorogenic derivatization. The separation of derivatives was performed on a C-18 column (3 mu m, 83 x 4.6 mm id) with a mobile phase consisting of acetonitrile-water-ethanol (63.5 + 35.5 + 1.0 v/v) containing 3.0 mmol l(-1) imidazole and 0.5 mmol l(-1) oxalic acid and with a pH of 6.2. Peroxyoxalate chemiluminescence detection was carried out by using bis(2-nitrophenyl) oxalate and hydrogen peroxide as chemilumigenic reagents. The quantitative data obtained (calibration graphs, detection limits, etc.) were analogous to those published previously. Groundwater samples were analysed using the proposed method. Data including the total amounts of secondary amines plus N-nitrosamines, the amount of secondary amines and results of blank experiments from the chromatograms for individual water sample were calculated, then the final concentrations of N-nitrosamines and secondary amines in each water sample were obtained simultaneously. The application of this procedure for determination of N-nitrosamines and corresponding secondary amines in water samples at pmol l(-1) and fmol l(-1) levels was successfully achieved. The recoveries of various N-nitrosamines and secondary amines added to groundwater samples were excellent (greater than or equal to 95% for all except two).
引用
收藏
页码:1147 / 1151
页数:5
相关论文
共 14 条
[1]  
BAKER JK, 1978, IARC SCI PUBL, V19, P19
[2]   SENSITIVE ASSAY SYSTEM FOR NITROSAMINES UTILIZING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
FU, CG ;
XU, HD ;
WANG, Z .
JOURNAL OF CHROMATOGRAPHY, 1993, 634 (02) :221-227
[3]  
FU CG, 1994, FENXI CESHI XUEBAO, V13, P28
[4]  
FU CG, 1985, CHIN J ANAL CHEM, V13, P595
[5]  
HOW LM, 1980, ANAL METHODS N NITRO
[6]   PREDICTION OF THE DETECTION RANGES FOR HPLC-PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION SYSTEM OF FLUORESCENT COMPOUNDS [J].
IMAI, K ;
NISHITANI, A ;
TSUKAMOTO, Y .
CHROMATOGRAPHIA, 1987, 24 :77-81
[7]   ARYL OXALATE CHEMI-LUMINESCENCE DETECTION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IMAI, K ;
WEINBERGER, R .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1985, 4 (07) :170-175
[8]   DETERMINATION OF FLUORESCENT COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMI-LUMINESCENCE DETECTION [J].
KOBAYASHI, S ;
IMAI, K .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :424-427
[9]   FACILE AND EFFECTIVE CHEMILUMINESCENCE DEMONSTRATION EXPERIMENT [J].
MOHAN, AG ;
TURRO, NJ .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :528-529
[10]  
OETINGER PE, 1973, ANAL LETT, V6, P731