BONE-GRAFT TRANSLATION OF 4 UPPER CERVICAL-SPINE FIXATION TECHNIQUES IN A CADAVERIC MODEL

被引:40
作者
CRISCO, JJ
PANJABI, MM
ODA, T
GROB, D
DVORAK, J
机构
[1] OSAKA UNIV,SCH MED,DEPT ORTHOPED SURG,SUITA,OSAKA 565,JAPAN
[2] SCHULTHESS CLIN,DEPT ORTHOPED SURG,SPINE UNIT,ZURICH,SWITZERLAND
[3] SCHULTHESS CLIN,DEPT NEUROL,SPINE UNIT,ZURICH,SWITZERLAND
关键词
UPPER CERVICAL; FIXATION; BIOMECHANICS; TRANSLATION; LAXITY;
D O I
10.1002/jor.1100090609
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The goal of spinal fixation is to promote bony fusion by restricting motion at the site of the bone graft. Therefore, in order to evaluate the efficiency of various cervical fixation techniques, we determined the translations at the posterior arch of C1 for four C1-C2 posterior techniques: Gallie, Brooks, Magerl, and Halifax. Our model was the cadaveric specimen, with extensive soft tissue injury: transection of the alar, transverse, and capsular ligaments. Under three-dimensional physiological loading, we recorded the motion of C1 relative to C2, and calculated the translations at the surface of the graft in three dimensions, 10 specimens being tested intact, injured, and instrumented with each of the techniques. We assumed that translational laxity or neutral zone was the critical motion parameter and evaluated it, quantified herein as the neutral zone, at seven points at the graft site. The three-dimensional neutral zone translations were analyzed by their axial and shear components. We found that there was no significant difference with the fixation techniques in the average axial translation (Brooks: 1.1 mm; Magerl: 1.3 mm; Gallie: 1.5 mm; and Halifax: 0.5 mm). In shear, the Magerl averaged 1 mm, which was significantly less than the Gallie (2.1 mm). The Brooks (1.6 mm) and Halifax (I mm) were not different from each other, Magerl, or Gallie. We propose that evaluation by translational laxity (neutral zone) at the graft site is a noteworthy concept in biomechanical analysis.
引用
收藏
页码:835 / 846
页数:12
相关论文
共 35 条
[1]  
BRAAKMAN R, 1971, INJURIES CERVICAL SP, P3
[2]   ATLANTO-AXIAL ARTHRODESIS BY WEDGE COMPRESSION METHOD [J].
BROOKS, AL ;
JENKINS, EB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :279-284
[3]  
CHAO EYS, 1989, CLIN ORTHOPAEDICS, V241, P24
[4]  
CRISCO JJ, 1989, THESIS YALE U NEW HA, P48
[5]  
EULER L, 1744, CURVAS ELASTICIS
[6]   BIOMECHANICAL COMPARISONS OF SPINAL FRACTURE MODELS AND THE STABILIZING EFFECTS OF POSTERIOR INSTRUMENTATIONS [J].
FERGUSON, RL ;
TENCER, AF ;
WOODARD, P ;
ALLEN, BL .
SPINE, 1988, 13 (05) :453-460
[7]  
Fried L C, 1973, J Bone Joint Surg Br, V55, P490
[8]  
Gallie WE., 1939, AM J SURG, V46, P495, DOI DOI 10.1016/S0002-9610(39)90309-0
[9]   POSTERIOR PLATING OF THE CERVICAL-SPINE - A BIOMECHANICAL COMPARISON OF DIFFERENT POSTERIOR FUSION TECHNIQUES [J].
GILL, K ;
PASCHAL, S ;
CORIN, J ;
ASHMAN, R ;
BUCHOLZ, RW .
SPINE, 1988, 13 (07) :813-816
[10]   A TECHNIQUE TO EVALUATE AN INTERNAL SPINAL DEVICE BY USE OF THE SELSPOT SYSTEM - AN APPLICATION TO LUQUE CLOSED-LOOP [J].
GOEL, VK ;
NYE, TA ;
CLARK, CR ;
NISHIYAMA, K ;
WEINSTEIN, JN .
SPINE, 1987, 12 (02) :150-159