NON-LINEAR POLYCHROMATIC AND NOISE ARTIFACTS IN X-RAY COMPUTED-TOMOGRAPHY IMAGES

被引:29
作者
DUERINCKX, AJ [1 ]
MACOVSKI, A [1 ]
机构
[1] STANFORD UNIV,DEPT ELECT ENGN,INFORMAT SYST LAB,STANFORD,CA 94305
关键词
Artifacts; Computed tomography; Noise; Polychromaticity;
D O I
10.1097/00004728-197908000-00015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The variance of the image noise in computed X-ray transmission tomography (CT) due to quantum noise is in a first approximation a nonlinear function of X-ray attenuation. Beam hardening in CT is also a nonlinear function of attenuation. We present a theoretical study of both phenomena. Computer simulations and numerical results show that both nonlinear dependencies have quite similar effects on image quality. We also show how the two-dimensional distribution of the noise variance in a CT image is a weighted superposition of images obtained by backprojecting integer powers of the noiseless projection data corresponding to the scanned object. The streak-like pattern in the image noise due to the anisotropic nature of the noise crosscorrelation function is discussed. We also discuss how these nonlinear phenomena affect noise filtering and tissue characterization using statistical parameters. © 1979 Raven Press, New York.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 20 条
[1]   OPTIMAL PROCESSING OF COMPUTED TOMOGRAPHY IMAGES USING EXPERIMENTALLY MEASURED NOISE PROPERTIES [J].
ALVAREZ, RE ;
STONESTROM, JP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (01) :77-84
[2]  
BARRETT H H, 1976, Computers in Biology and Medicine, V6, P307, DOI 10.1016/0010-4825(76)90068-8
[3]   BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[4]   NOISE DUE TO PHOTON-COUNTING STATISTICS IN COMPUTED X-RAY TOMOGRAPHY [J].
CHESLER, DA ;
RIEDERER, SJ ;
PELC, NJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :64-74
[5]  
DICHIRO G, 1978, J COMPUT ASSIST TOMO, V2, P65
[6]   POLYCHROMATIC STREAK ARTIFACTS IN COMPUTED TOMOGRAPHY IMAGES [J].
DUERINCKX, AJ ;
MACOVSKI, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (04) :481-487
[7]  
DUERINCKX AJ, 1978, 64TH RAD SOC N AM SC
[8]  
DUERINCKX AJ, 1978, SPIE, V152, P19
[9]   METHOD FOR CORRECTING BONE INDUCED ARTIFACTS IN COMPUTED TOMOGRAPHY SCANNERS [J].
JOSEPH, PM ;
SPITAL, RD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (01) :100-108
[10]  
KIJEWSKI P K, 1978, Medical Physics (Woodbury), V5, P209, DOI 10.1118/1.594429