SWELLING AND DISSOLUTION KINETICS DURING PEPTIDE RELEASE FROM ERODIBLE ANIONIC GEL BEADS

被引:12
作者
LEE, PI [1 ]
机构
[1] UNIV TORONTO,DEPT CHEM ENGN & APPL CHEM,TORONTO M5S 2S2,ON,CANADA
关键词
SWELLING AND DISSOLUTION KINETICS; FRONT SYNCHRONIZATION; POLY(METHYL METHACRYLATE-CO-METHACRYLIC ACID); SPHERICAL ERODIBLE BEADS; GROWTH HORMONE RELEASING PEPTIDE RELEASE;
D O I
10.1023/A:1018902404036
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The transient dynamic swelling and dissolution behavior during the release of a growth hormone releasing PePtide, [D-Trp2-D-Phe5]GHRP, from erodible, non-cross-linked poly(methyl methacrylate-co-methacrylic acid) (PMMA/MAA) beads has been investigated at pH 7.4 as a function of buffer concentration. Although the swelling front penetration shows a ionization-limited behavior similar to that of nonerodible cross-linked PMMA/MAA beads, the normalized diameter of the polymer beads exhibits a brief initial rise followed by an extended linear decline due to establishment of the polymer dissolution process. This is consistent with the general kinetic scheme of dissolution of glassy polymers originally predicted for the slab geometry. In all cases, the initial gel thickness increases as a result of the ionization and swelling of the glassy PMMA/MAA beads. This is followed by an extended period of constant gel thickness due to the onset of polymer dissolution and the synchronization of movement of the swelling and dissolution fronts. The resulting constant gel layer thickness as well as the onset and duration of front synchronization shows an increasing trend with decreasing buffer concentrations. As a result, the corresponding peptide release is slower and the release duration longer at lower buffer concentrations. This is believed to be the first time that a synchronization of swelling and dissolution fronts has been documented for a spherical erodible sample. Although such synchronization of fronts does not result in a constant rate of peptide release due to the spherical geometry, some non-Fickian release characteristics have been observed.
引用
收藏
页码:980 / 985
页数:6
相关论文
共 15 条
  • [1] COLOMBO P, 1987, Acta Pharmaceutica Technologica, V33, P15
  • [2] DRUG POLYMER MATRIX SWELLING AND DISSOLUTION
    HARLAND, RS
    GAZZANIGA, A
    SANGALLI, ME
    COLOMBO, P
    PEPPAS, NA
    [J]. PHARMACEUTICAL RESEARCH, 1988, 5 (08) : 488 - 494
  • [3] HELLER J, 1985, Journal of Controlled Release, V2, P167, DOI 10.1016/0168-3659(85)90042-2
  • [4] HYDROPHOBIC ANIONIC GEL BEADS FOR SWELLING-CONTROLLED DRUG DELIVERY
    KIM, CJ
    LEE, PI
    [J]. PHARMACEUTICAL RESEARCH, 1992, 9 (02) : 195 - 199
  • [5] EFFECT OF LOADING ON SWELLING-CONTROLLED DRUG RELEASE FROM HYDROPHOBIC POLYELECTROLYTE GEL BEADS
    KIM, CJ
    LEE, PI
    [J]. PHARMACEUTICAL RESEARCH, 1992, 9 (10) : 1268 - 1274
  • [6] LEE P I, 1986, Journal of Controlled Release, V4, P1, DOI 10.1016/0168-3659(86)90027-1
  • [7] LEE P I, 1987, Journal of Controlled Release, V6, P207, DOI 10.1016/0168-3659(87)90077-0
  • [8] LEE PI, 1980, J MEMBRANE SCI, V7, P255
  • [9] EFFECT OF GEOMETRY ON SOLVENT FRONT PENETRATION IN GLASSY-POLYMERS
    LEE, PI
    KIM, CJ
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1992, 65 (1-2) : 77 - 92
  • [10] Lee PI, 1992, TREATISE CONTROLLED, P155