SEALED INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY .3. OPTIMIZATION OF EXPERIMENTAL-VARIABLES

被引:9
作者
JAHL, MJ
BARNES, RM
机构
关键词
SEALED PLASMA; STATIC PLASMA; GAS ANALYSIS; INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; ARSINE AND PHOSPHINE DETERMINATION;
D O I
10.1039/ja9920700825
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Experimental variables for a sealed inductively coupled plasma (ICP) argon discharge are investigated and optimized for the emission spectroscopic determination of arsenic and phosphorus introduced as arsine and phosphine. Important parameters include generator power, gas modifier mixture, discharge container geometry, operating pressure and operating procedure. Less important are the total gas flow rate, container preparation and construction and induction coil geometry. The optimum geometry is a 40 mm quartz sphere with a larger induction coil (almost-equal-to 45 mm in diameter). Detection limits for arsenic and phosphorus are in the low ppb range for a 950 W, 27.12 MHz argon-4% hydrogen ICP.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 13 条
[1]   THEORY OF TRACE-ELEMENT DETECTION FROM A STATIC THERMAL INDUCTION PLASMA [J].
ECKERT, HU .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1978, 33 (09) :591-608
[2]  
ECKERT HU, 1977, ICP INFORM NEWSL, V2, P327
[3]   DETERMINATION OF ARSENIC IN AN ORGANIC-PHASE BY COUPLING CONTINUOUS-FLOW EXTRACTION - HYDRIDE GENERATION WITH INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
GARCIA, AM ;
URIA, JES ;
SANZMEDEL, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) :581-585
[4]   HYDRIDE GENERATION CONDENSATION SYSTEM WITH AN INDUCTIVELY COUPLED ARGON PLASMA POLYCHROMATOR FOR DETERMINATION OF ARSENIC, BISMUTH, GERMANIUM, ANTIMONY, SELENIUM, AND TIN IN FOODS [J].
HAHN, MH ;
WOLNIK, KA ;
FRICKE, FL ;
CARUSO, JA .
ANALYTICAL CHEMISTRY, 1982, 54 (07) :1048-1052
[5]   CONTINUOUS HYDRIDE GENERATION FOR SIMULTANEOUS MULTIELEMENT DETECTION WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HEITKEMPER, DT ;
CARUSO, JA .
APPLIED SPECTROSCOPY, 1990, 44 (02) :228-234
[6]   SEALED INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROSCOPY .2. DETERMINATION OF PHOSPHORUS [J].
JAHL, MJ ;
BARNES, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :923-934
[7]   SEALED INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY - INSTRUMENTATION DEVELOPMENT [J].
JAHL, MJ ;
JACKSIER, T ;
BARNES, RM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :653-660
[8]   INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRIC DETERMINATION OF ARSENIC, ANTIMONY, TIN, BISMUTH, SELENIUM AND TELLURIUM IN LEADS AND REFINED COPPERS [J].
LOPEZ, TD ;
MARIN, MTL ;
COEDO, AG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (03) :447-452
[9]   COMPARISON OF FLOW-INJECTION AND CONTINUOUS SAMPLE INTRODUCTION FOR AUTOMATIC SIMULTANEOUS DETERMINATION OF AS, SB, AND SE BY HYDRIDE GENERATION AND INDUCTIVELY COUPLED PLASMA OPTICAL-EMISSION SPECTROMETRY [J].
PYEN, GS ;
BROWNER, RF .
APPLIED SPECTROSCOPY, 1988, 42 (03) :508-512
[10]   TRACE ANALYSIS BY MICROWAVE EXCITATION OF SEALED SAMPLES .3. DETERMINATION OF 0.005-25 NG OF TE AND 0.25-25 NG OF SE IN 0.5 ML OF AQUEOUS-SOLUTION [J].
VANMONTF.PF ;
AGTERDEN.J .
TALANTA, 1974, 21 (06) :660-663