DETERMINATION OF PULSE-WAVE VELOCITIES WITH COMPUTERIZED ALGORITHMS

被引:240
作者
CHIU, YC
ARAND, PW
SHROFF, SG
FELDMAN, T
CARROLL, JD
机构
[1] Section of Cardiology, Department of Medicine, University of Chicago Hospitals Chicago, IL
关键词
D O I
10.1016/0002-8703(91)90153-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Careful determination of pulse wave velocity is important in the study of arterial viscoelastic properties, wave reflections, and ventricular-arterial interactions. In spite of its increasingly widespread use, there is as yet no standardized method for its determination. Most studies have manually identified the transit time of the pressure wave front as it travels over a known distance in the arterial system, but the issues of accuracy and reproducibility have not been addressed. This study was designed to investigate the efficacy of four computerized algorithms in the determination of pulse wave velocities in invasive as well as in noninvasive pressure determinations. The four methods were the identification of: (1) the point of minimum diastolic pressure, (2) the point at which the first derivative of pressure is maximum, (3) the point at which the second derivative of pressure is maximum, and (4) the point yielded by the intersection of a line tangent to the initial systolic upstroke of the pressure tracing and a horizontal line through the minimum point. High-fidelity aortic pressure recordings were obtained in 26 patients with a multi-sensor micromanometer catheter. Noninvasive brachial and radial pressure waveforms were recorded in 11 volunteers with external piezoelectric transducers. The results show that the first derivative method consistently provided results that were different from the other methods for both the invasive and noninvasive methods because of changes in the structure of the upstroke as the arterial pulse propagates distally. Although the minimum method worked well for the invasive determiantions, it was erratic with the noninvasive determiantions, probably because of the higher amount of noise and reflection in the latter. Among the four algorithms, the second derivative and the intersecting tangents methods worked well with both invasive and noninvasive determinations with mean variation coefficients of less than 7% and correlation coefficients between the methods of greater than 0.90 for all data. In conclusion, computerized algorithms allow accurate determiantion of pulse wave velocity in invasively and noninvasively measured arterial pressure waveforms.
引用
收藏
页码:1460 / 1470
页数:11
相关论文
共 20 条
[1]   DISPERSION AND ATTENUATION OF SMALL ARTIFICIAL PRESSURE WAVES IN CANINE AORTA [J].
ANLIKER, M ;
HISTAND, MB ;
OGDEN, E .
CIRCULATION RESEARCH, 1968, 23 (04) :539-&
[2]  
ANTONION A, 1979, DIGITAL FILTERS
[3]   Measurements of pulse wave velocity [J].
Bazett, HC ;
Dreyer, NB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1922, 63 (01) :94-116
[4]  
Dahlquist G., 1974, NUMERICAL METHODS
[5]  
FULTON JS, 1930, AM J PHYSIOL, V69, P387
[6]   A CRITIQUE - RELATIONSHIP OF TIME DERIVATIVE OF PRESSURE TO BLOOD FLOW [J].
GREENFIELD, JC ;
FRY, DL .
JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (06) :1141-+
[7]   TRANSDUCER SYSTEM FOR THE NONINVASIVE RECORDING OF ARTERIAL-PRESSURE CONTOURS [J].
KARR, SG ;
KARWOSKI, T ;
JACOBS, JE ;
MOCKROS, LF .
ANNALS OF BIOMEDICAL ENGINEERING, 1985, 13 (05) :425-442
[8]  
KARR SG, 1982, THESIS NW U
[9]   ARTERIAL WAVE REFLECTION IN HEART-FAILURE [J].
LASKEY, WK ;
KUSSMAUL, WG .
CIRCULATION, 1987, 75 (04) :711-722
[10]  
LASZT L, 1982, HEMODYNAMICS