VOLUMETRIC CT ANALYSIS OF HEPATIC-TUMORS

被引:32
作者
MOSS, AA
CANN, CE
FRIEDMAN, MA
MARCUS, FS
RESSER, KJ
BERNINGER, W
机构
[1] UNIV CALIF SAN FRANCISCO, DEPT RADIOL, SAN FRANCISCO, CA 94143 USA
[2] UNIV CALIF SAN FRANCISCO, DEPT MED, SAN FRANCISCO, CA 94143 USA
[3] GE, CTR RES & DEV, SCHENECTADY, NY 12345 USA
关键词
D O I
10.1097/00004728-198110000-00022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Current methods of measuring [human] hepatic volume and the percent of hepatic parenchyma replaced by tumor are crude, yet clinical decisions are often based on these imprecise measurements. A new computed tomographic (CT) assisted volume calculatory program to accurately assess hepatic volume, is described. A new computer program to discriminate tumor from normal liver and thus provide tumor volume measurements is also presented. The potential usefulness of these techniques is illustrated by an analysis of pre- and posttherapy CT scans and calculation of changes in hepatic volume and in the volume of hepatic tumor. Analysis revealed small changes in liver volume could be accompanied by substantial changes in tumor volume and vice versa. Quantitative CT techniques allow for rapid, reproducible measurements of liver and tumor volume. Small changes in organ volume may be accompanied by substantial changes in tumor volume.
引用
收藏
页码:714 / 718
页数:5
相关论文
共 19 条
[1]   LEUKOENCEPHALOPATHY FOLLOWING HIGH-DOSE INTRAVENOUS METHOTREXATE CHEMOTHERAPY - QUANTITATIVE ASSESSMENT OF WHITE MATTER ATTENUATION USING COMPUTED TOMOGRAPHY [J].
ALLEN, JC ;
THALER, HT ;
DECK, MDF ;
ROTTENBERG, DA .
NEURORADIOLOGY, 1978, 16 :44-47
[2]  
BIELLO DR, 1978, RADIOLOGY, V127, P159, DOI 10.1148/127.1.159
[3]   PRECISE MEASUREMENT OF VERTEBRAL MINERAL-CONTENT USING COMPUTED-TOMOGRAPHY [J].
CANN, CE ;
GENANT, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) :493-500
[4]  
FIKE JR, 1980, RADIAT RES, V83, P378
[5]  
FRIEDMAN MA, 1981, CLIN RES, V29
[6]   HEPATIC VASCULAR BED [J].
GREENWAY, CV ;
STARK, RD .
PHYSIOLOGICAL REVIEWS, 1971, 51 (01) :23-+
[7]   COMPUTED TOMOGRAPHIC GUIDED LIVER-BIOPSY USING THE MENGHINI NEEDLE [J].
HAAGA, JR ;
VANEK, J .
RADIOLOGY, 1979, 133 (02) :405-408
[8]   ACCURATE MEASUREMENT OF LIVER, KIDNEY, AND SPLEEN VOLUME AND MASS BY COMPUTERIZED AXIAL-TOMOGRAPHY [J].
HEYMSFIELD, SB ;
FULENWIDER, T ;
NORDLINGER, B ;
BARLOW, R ;
SONES, P ;
KUTNER, M .
ANNALS OF INTERNAL MEDICINE, 1979, 90 (02) :185-187
[9]   COMPUTED-TOMOGRAPHY APPLIED TO RADIOTHERAPY TREATMENT PLANNING - TECHNIQUES AND RESULTS [J].
HOBDAY, P ;
HODSON, NJ ;
HUSBAND, J ;
PARKER, RP ;
MACDONALD, JS .
RADIOLOGY, 1979, 133 (02) :477-482
[10]   CT OF RADIATION-INDUCED HEPATIC-INJURY [J].
JEFFREY, RB ;
MOSS, AA ;
QUIVEY, JM ;
FEDERLE, MP ;
WARA, WM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (03) :445-448