GENERATION OF CONTRAST-CARRYING LIPOSOMES OF DEFINED SIZE WITH A NEW CONTINUOUS HIGH-PRESSURE EXTRUSION METHOD

被引:43
作者
SCHNEIDER, T [1 ]
SACHSE, A [1 ]
ROSSLING, G [1 ]
BRANDL, M [1 ]
机构
[1] UNIV FREIBURG,INST PHARMAZEUT,D-79140 FREIBURG,GERMANY
关键词
LIPOSOME; CONTRAST AGENT; GD-DTPA; IOPROMIDE; EXTRUSION; CONTINUOUS PROCESS; HIGH PRESSURE; ENCAPSULATION EFFICIENCY;
D O I
10.1016/0378-5173(94)00245-Z
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A novel continuous high pressure extrusion method was evaluated for the generation of radiopaque and paramagnetic liposomes. The magnetic resonance contrast agent gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) as well as the X-ray contrast agent iopromide were used as water-soluble model substances for liposomal encapsulation. The continuous process, which is introduced here, allows the fast and efficient extrusion of large batches of liposomal preparations with maximum flow rates of 500 ml/min. Applying high pressures up to 10.5 MPa, MLV prepared by the film method were sequentially extruded through polycarbonate membranes of decreasing pore size. Encapsulation efficiency was found to be dependent on lipid composition and concentration, amount of contrast agent in the preparation as well as choice of final pore size for extrusion, Application of freeze-thaw cycles markedly improved the entrapment of iopromide, whereas for Gd-DTPA freeze-thaw surprisingly turned out to have only minor effects. Entrapment values rose with increasing lipid concentration and fell sharply with increasing solute concentration. Mean liposome diameters could be varied using polycarbonate membranes of differing pore sizes. Smaller final pore sizes led to vesicle populations with smaller mean diameters and lower encapsulation efficiencies. Excellent maximum encapsulation efficiencies of more than 50% for iopromide and over 60% for Gd-DTPA were obtained for vesicles with mean diameters of around 100 nm, as determined by photon correlation spectroscopy (PCS) and confirmed by negative-staining electron microscopy. Employing medium contrast (100 mg/g iodine and 180 mu mol/g Gd) and lipid concentrations (150 mg/g), entrapment values as high as 40% for the X-ray and 50% for the paramagnetic contrast agent could still be achieved. Best results were obtained using a lipid mixture of soy phosphatidylcholine (SPC), cholesterol (Chol) and soy phosphatidylglycerol (SPG) in a molar ratio of 6:3:1 for iopromide and SPC, Chol 7:3 for Gd-DTPA. Liposomal preparations remained stable upon storage at 2-8 degrees C for 6 months. The new continuous high pressure extrusion method proved to be suitable for the generation of large volumes of stable, contrast-carrying liposomes with outstanding encapsulation efficiencies.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 23 条
[1]  
Amselem S., 1989, J LIPOSOME RES, V1, P287, DOI [10.3109/08982108909035998, DOI 10.3109/08982108909035998]
[2]  
AMSELEM S, 1993, LIPOSOME TECHNOLOGY, V1, P501
[3]  
AMSELEM S, 1993, J LIPOSOME RES, V1, P501
[4]  
Bally M. B., 1988, LIPOSOMES DRUG CARRI, P841
[5]   RADIOPAQUE LIPOSOMES - EFFECT OF FORMULATION CONDITIONS ON ENCAPSULATION EFFICIENCY [J].
BENITA, S ;
POLY, PA ;
PUISIEUX, F ;
DELATTRE, J .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (12) :1751-1755
[6]  
CARIDE V J, 1984, Magnetic Resonance Imaging, V2, P107, DOI 10.1016/0730-725X(84)90064-X
[7]   THE PRODUCTION AND EVALUATION OF CONTRAST-CARRYING LIPOSOMES MADE WITH AN AUTOMATIC HIGH-PRESSURE SYSTEM [J].
CHENG, KT ;
SELTZER, SE ;
ADAMS, DF ;
BLAU, M .
INVESTIGATIVE RADIOLOGY, 1987, 22 (01) :47-55
[8]   DETAILED TOXICITY STUDIES OF LIPOSOMAL GADOLINIUM-DTPA [J].
FRITZ, T ;
UNGER, E ;
WILSONSANDERS, S ;
AHKONG, QF ;
TILCOCK, C .
INVESTIGATIVE RADIOLOGY, 1991, 26 (11) :960-968
[9]   A PHOSPHOLIPID SPIN LABEL USED AS A LIPOSOME-ASSOCIATED MRI CONTRAST AGENT [J].
GRANT, CWM ;
BARBER, KR ;
FLORIO, E ;
KARLIK, S .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (04) :371-376
[10]   RADIO-OPAQUE LIPOSOMES FOR THE IMPROVED VISUALIZATION OF FOCAL LIVER-DISEASE BY COMPUTERIZED-TOMOGRAPHY [J].
HENZE, A ;
FREISE, J ;
MAGERSTEDT, P ;
MAJEWSKI, A .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1989, 13 (06) :455-462