AN EVALUATION OF A 30-GAUGE NEEDLE FOR SPINAL-ANESTHESIA FOR CESAREAN-SECTION

被引:40
作者
LESSER, P
BEMBRIDGE, M
LYONS, G
MACDONALD, R
机构
[1] ST JAMES UNIV HOSP,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
[2] HALIFAX ROYAL INFIRM,HALIFAX,ENGLAND
[3] HUDDERSFIELD ROYAL INFIRM,HUDDERSFIELD,ENGLAND
关键词
Anaesthesia; obstetric; Anaesthetic techniques; regional; spinal;
D O I
10.1111/j.1365-2044.1990.tb14451.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A 30‐gauge spinal needle was evaluated for Caesarean section, using a combined epidural/spinal technique, in 50 mothers. Spinal anaesthesia failed in six mothers and was inadequate in another six. General anaesthesia was required on one occasion. A 25% overall failure rate suggests that a 30‐gauge needle is not a practical proposition for routine clinical practice. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:767 / 768
页数:2
相关论文
共 3 条
[1]   SPINAL-ANESTHESIA WITH HYPERBARIC LIGNOCAINE FOR ELECTIVE CESAREAN-SECTION [J].
BEMBRIDGE, M ;
MACDONALD, R ;
LYONS, G .
ANAESTHESIA, 1986, 41 (09) :906-909
[2]  
LEE JA, 1985, LUMBAR PUNCTURE SPIN
[3]   EPIDURAL VERSUS COMBINED SPINAL EPIDURAL BLOCK FOR CESAREAN-SECTION [J].
RAWAL, N ;
SCHOLLIN, J ;
WESSTROM, G .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1988, 32 (01) :61-66