RELATIONSHIP OF BIOIMPEDANCE TO THERMODILUTION AND ECHOCARDIOGRAPHIC MEASUREMENTS OF CARDIAC-FUNCTION

被引:25
作者
SPINALE, FG
SMITH, AC
CRAWFORD, FA
机构
关键词
D O I
10.1097/00003246-199004000-00013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Bioimpedance cardiography has been suggested as a noninvasive means to monitor cardiac function. However, this method has not been compared to more conventional techniques such as echocardiography. This study compared simultaneously obtained thermodilution cardiac output and right ventricular ejection fraction (RVEF), and echocardiographic left ventricular fractional shortening (LVFS), to bioimpedance cardiac output and the maximum first derivative of the bioimpedance signal (dZ/dt(max)) during positive inotropic stimulation and preload reduction. Eight pigs were instrumented with a rapid response thermistor (positioned in the pulmonary artery) and bioimpedance electrodes. Simultaneous thermodilution, echocardiographic, and bioimpedance measurements were performed at baseline after 5, 10, and 15 min of isoproterenol infusion (0.5 μg/kg·min). In six pigs, measurements were also performed after balloon occlusion of the inferior vena cava. A significant correlation was observed between LVFS and dZ/dt(max) (r = .88, n = 35) over all time points. Thermodilution and bioimpedance cardiac output were in close agreement (r = .92, n = 35). However, bioimpedance overestimated cardiac output in the very low and high output states. The mean difference between thromodilution and bioimpedance was significantly correlated with thermodilution cardiac output over a wide hemodynamic range. The peak first derivative of the bioimpedance signal dZ/dt(max) may provide a noninvasive index of ventricular pump performance. Further studies are required to evaluate the diagnostic value of bioimpedance cardiography in the clinical setting.
引用
收藏
页码:414 / 418
页数:5
相关论文
共 20 条
[1]   COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[2]   CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[3]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   MEASUREMENT OF EJECTION FRACTION BY BIOIMPEDANCE METHOD [J].
CAPAN, LM ;
BERNSTEIN, DP ;
PATEL, KP ;
SANGER, J ;
TURNDORF, H .
CRITICAL CARE MEDICINE, 1987, 15 (04) :402-402
[7]   CARDIAC-OUTPUT IN EXERCISE BY IMPEDANCE CARDIOGRAPHY DURING BREATH HOLDING AND NORMAL BREATHING [J].
DUQUESNAY, MC ;
STOUTE, GJ ;
HUGHSON, RL .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (01) :101-107
[8]   THE USE OF IMPEDANCE CARDIOGRAPHY IN HEART-FAILURE [J].
HUBBARD, WN ;
FISH, DR ;
MCBRIEN, DJ .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1986, 12 (01) :71-79
[9]   MEASUREMENT OF EJECTION FRACTION BY THERMAL DILUTION TECHNIQUES [J].
KAY, HR ;
AFSHARI, M ;
BARASH, P ;
WEBLER, W ;
ISKANDRIAN, A ;
BEMIS, C ;
HAKKI, AH ;
MUNDTH, ED .
JOURNAL OF SURGICAL RESEARCH, 1983, 34 (04) :337-346
[10]  
KUBICEK WG, 1974, BIOMED ENG, V9, P410