COMPARISON OF POLYBUTADIENE-COATED ALUMINA AND OCTADECYL-BONDED SILICA FOR SEPARATIONS OF PROTEINS AND PEPTIDES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:30
作者
HAKY, JE [1 ]
RAGHANI, A [1 ]
DUNN, BM [1 ]
机构
[1] UNIV FLORIDA, DEPT BIOCHEM & MOLEC BIOL, GAINESVILLE, FL 32610 USA
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 541卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(01)96002-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chromatographic retention and separations of proteins and peptides on a novel polybutadienecoated alumina (PBDA) high-performance liquid chromatographic stationary phase are compared to those obtained on a widely-used polymeric octadecylsilane (ODS) phase. Using acetonitrile-water mobile phase gradients containing 0.1% trifluoroacetic acid, the average peak capacities (which are inversely proportional to average peak widths) and peak resolutions obtained for chromatograms of mixtures of ribonuclease A, cytochrome c, lysozyme and carbonic anhydrase are five times lower on a column packed with PBDA than on one packed with ODS. Irreversible adsorption causes increases in column back-pressure during successive analyses of protein solutions on PBDA phases and 50% reductions in protein peak areas on the PBDA phase compared to ODS. In contrast to those results, peak capacities, resolutions and peak areas for synthetic octapeptides on the PBDA and ODS phases are more comparable to each other. Chromatographic capacity factors of 31 low-molecular-weight organic compounds on PBDA and ODS columns are shown to correlate well. The critical concentrations of organic modifier required to elute proteins and octapeptides from PBDA columns are lower than that required for ODS, but still correlate linearly with corresponding values from ODS columns. It is concluded from these results that the retentions of peptides, proteins and smaller molecules on both the PBDA and ODS phases are governed by similar hydrophobic interaction mechanisms, while peak broadening due to mass transfer resistance increases more rapidly with solute size on the PBDA stationary phase than it does on ODS. The increase in solute mass transfer resistance with solute size on the PBDA column is attributed to solute interactions with the uniquely-shaped PBDA particles.
引用
收藏
页码:303 / 315
页数:13
相关论文
共 24 条
  • [1] COMPARISON OF REVERSED-PHASE COLUMNS FOR THE SEPARATION OF TRYPTIC PEPTIDES BY GRADIENT ELUTION - CORRELATION OF EXPERIMENTAL RESULTS AND MODEL PREDICTION
    BANES, AJ
    LINK, GW
    SNYDER, LR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 326 (JUN): : 419 - 431
  • [2] BBENSON JR, 1980, J CHROMATOGR SCI, V22, P386
  • [3] SYNTHESES OF STATIONARY PHASES FOR REVERSED-PHASE LC USING SILANIZATION AND POLYMER COATING
    BIENVOGELSANG, U
    DEEGE, A
    FIGGE, H
    KOHLER, J
    SCHOMBURG, G
    [J]. CHROMATOGRAPHIA, 1984, 19 : 170 - 179
  • [4] SEPARATION OF PROTEINS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. OPTIMIZING THE COLUMN
    BURTON, WG
    NUGENT, KD
    SLATTERY, TK
    SUMMERS, BR
    SNYDER, LR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 443 : 363 - 379
  • [5] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS AND POLYPEPTIDES ON POLYSTYRENE-COATED SILICA SUPPORTS
    DAVANKOV, VA
    KURGANOV, AA
    UNGER, KK
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 500 : 519 - 530
  • [6] FACTORS INFLUENCING THE PERFORMANCE OF PEPTIDE-MAPPING BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DONG, MW
    TRAN, AD
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 499 : 125 - 139
  • [7] A SYSTEMATIC SERIES OF SYNTHETIC CHROMOPHORIC SUBSTRATES FOR ASPARTIC PROTEINASES
    DUNN, BM
    JIMENEZ, M
    PARTEN, BF
    VALLER, MJ
    ROLPH, CE
    KAY, J
    [J]. BIOCHEMICAL JOURNAL, 1986, 237 (03) : 899 - 906
  • [8] THE SYNTHESIS, PURIFICATION, AND EVALUATION OF A CHROMOPHORIC SUBSTRATE FOR PEPSIN AND OTHER ASPARTYL PROTEASES - DESIGN OF A SUBSTRATE BASED ON SUBSITE PREFERENCES
    DUNN, BM
    KAMMERMANN, B
    MCCURRY, KR
    [J]. ANALYTICAL BIOCHEMISTRY, 1984, 138 (01) : 68 - 73
  • [9] COMPARISON OF OCTADECYL-BONDED ALUMINA AND SILICA FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HAKY, JE
    VEMULAPALLI, S
    WIESERMAN, LF
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 505 (02): : 307 - 318
  • [10] COMPARISON OF OCTADECYL-BONDED ALUMINA AND OTHER STATIONARY PHASES FOR LIPOPHILICITY ESTIMATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HAKY, JE
    VEMULAPALLI, S
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (15): : 3111 - 3131