WATT-HOUR METER ACCURACY ON INTEGRAL-CYCLE-CONTROLLED RESISTANCE LOADS

被引:3
作者
EMANUEL, AE [1 ]
HYNDS, BM [1 ]
LEVITSKY, FJ [1 ]
机构
[1] NEW ENGLAND ELECTR SYST,WORCESTER,MA
来源
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS | 1979年 / 98卷 / 05期
关键词
D O I
10.1109/TPAS.1979.319473
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The change in performance of induction watthour meters when measuring integral-cycle-controlled resistance loads was studied. A simple mathematical model is used to explain the main cause for error. Test results for representative meters show that meters on integral cycle speed up, resulting in substantial positive errors. When mixed loads are monitored, the error becomes small and within commercially acceptable limits. Copyright © 1979 by The Institute of Electrical and Electronics Engineers. Inc.
引用
收藏
页码:1583 / 1590
页数:8
相关论文
共 5 条
[1]  
Baggot A. J., 1974, International Conference on Sources and Effects of Power System Disturbances, P261
[2]   WATTHOUR METER ACCURACY ON SCR CONTROLLED RESISTANCE LOADS [J].
DOWNING, WC .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (04) :1083-1089
[3]   ANALYSIS OF THYRISTOR-CONTROLLED SINGLE-PHASE LOADS WITH INTEGRAL-CYCLE TRIGGERING [J].
LINGARD, BW ;
JOHNSON, RW ;
SHEPHERD, W .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1970, 117 (03) :607-&
[4]   THYRISTOR CONTROL OF RESISTIVE AND SERIES DC MOTOR LOADS USING INTEGRAL-CYCLE SWITCHING [J].
SHEPHERD, W ;
GALLAGHER, PJ .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1974, IA10 (05) :657-661
[5]  
Tschappu F., 1973, Landis & Gyr Review, V20, P20