THE LARYNGEAL MASK AIRWAY - ANESTHETIC GAS LEAKAGE AND FIBEROPTIC CONTROL OF POSITIONING

被引:28
作者
FULLEKRUG, B
POTHMANN, W
WERNER, C
ESCH, JSA
机构
[1] Department of Anesthesiology, University Hospital Eppendorf, Hamburg
关键词
Airway management-laryngeal mask airway; position; fit; anesthetics-nitrous oxide; waste gas; measurement techniques-fiberoptic laryngoscopy; infrared nitrous oxide analysis; ventilation-intermittent positive-pressure ventilation; positive end-expiratory pressure;
D O I
10.1016/0952-8180(93)90097-X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To examine the anesthetic gas leakage and prelaryngeal position of the laryngeal mask airway (LMA). Design: Clinical trial evaluating LMA ventilation conditions. Setting: Lithotripsy room of a urology clinic at a university hospital. Patients: 100 adult ASA physical status I and II patients undergoing general anesthesia for kidney stone lithotripsy. Interventions: Anesthesia was induced with propofol 1.5 to 2.5 mg/kg intravenously (IV) and fentanyl 1 to 1.5 mug/kg IV and maintained with isoflurane plus nitrous oxide in oxygen. Measurements and Main Results: Waste anesthetic gas concentration, an indicator of mask tightness during intermittent positive-pressure ventilation, was measured using an infrared oxide analyzer. LMA position in relation to laryngeal skeleton was assessed using fiberoptic laryngoscopy. The LMA was found to be gastight in 62% of patients, with a peak airway pressure up to 25 cmH2O. During peak airway pressure ventilation less than 10 cmH2O and during spontaneous ventilation, waste anesthetic gas contamination in the anesthesiologist's breathing zone was within legal limits in every case. During peak airway pressure ventilation up to 30 cmH2O, contamination was found within legal limits in 78% of all cases. Fiberoptic control showed a central position in 59% of cases, lateral deviations to the left or right in 29%, dorsal positions in 8%, and ventral positions in 4%. Incorrect ventral or dorsal positioning was related to forced reclining or forced flexion of the patient's head. There was no correlation between LMA position and tightness. The esophageal entrance was visible in 15 patients using high peak airway pressure greater than 25 cmH2O. Conclusions: The LMA is a new airway management technique with good qualities of tightness and ventilation conditions. However, contraindications such as patients with a full stomach, intra-abdominal surgery, high peak airway pressure, prolonged operation, and an inexperienced anesthesiologist apply.
引用
收藏
页码:357 / 363
页数:7
相关论文
共 24 条
[1]  
Brain, McGhee, McAteer, Thomas, Abu Saad, Bushman, The laryngeal mask airway. Development and preliminary trials of a new type of airway, Anaesthesia, 40, pp. 356-361, (1985)
[2]  
Brodrick, Webster, Nunn, The laryngeal mask airway. A study of 100 patients during spontaneous breathing, Anaesthesia, 44, pp. 238-241, (1989)
[3]  
Harris, Johnston, Collins, Heath, A new general anaesthetic technique for use in singers: the Brain laryngeal mask airway versus endotracheal intubation, J Voice, 4, pp. 81-85, (1990)
[4]  
Maltby, Loken, Watson, The laryngeal mask airway: clinical appraisal in 250 patients, Can J Anaesth, 37, pp. 509-513, (1990)
[5]  
Sarma, The use of a laryngeal mask airway in spontaneously breathing patients, Acta Anaesthesiol Scand, 34, pp. 669-672, (1990)
[6]  
Brain, Three cases of difficult intubation overcome by the laryngeal mask airway, Anaesthesia, 40, pp. 353-355, (1985)
[7]  
Calder, Ordman, Jackowski, Crockard, The Brain laryngeal mask airway. An alternative to emergency tracheal intubation, Anaesthesia, 45, pp. 137-139, (1990)
[8]  
DeMello, Kocan, The laryngeal mask in failed intubation, Anaesthesia, 45, pp. 689-690, (1990)
[9]  
Benumof, Management of the difficult adult airway. With special emphasis on awake tracheal intubation, Anasthesiology, 75, pp. 1087-1110, (1991)
[10]  
Sarma, Leman, Laryngeal mask and anaesthetic waste gas concentrations, Anaesthesia, 45, pp. 791-792, (1990)