HEPATIC METASTASES FROM COLORECTAL-CANCER - DETECTION AND FALSE-POSITIVE FINDINGS WITH HELICAL CT DURING ARTERIAL PORTOGRAPHY

被引:90
作者
SOYER, P
BLUEMKE, DA
HRUBAN, RH
SITZMANN, JV
FISHMAN, EK
机构
[1] JOHNS HOPKINS UNIV HOSP,DEPT RADIOL,BALTIMORE,MD 21205
[2] JOHNS HOPKINS UNIV HOSP,DEPT PATHOL,BALTIMORE,MD 21205
[3] JOHNS HOPKINS UNIV HOSP,DEPT SURG,BALTIMORE,MD 21205
关键词
COMPUTED TOMOGRAPHY (CT); HELICAL TECHNOLOGY; LIVER NEOPLASMS; DIAGNOSIS; PORTOGRAPHY;
D O I
10.1148/radiology.193.1.8090923
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the sensitivity and false-positive rate of helical computed tomography during arterial portography (CTAP) in the detection of hepatic metastases from colorectal cancer. MATERIALS AND METHODS: Preoperative helical CTAP was performed to examine 23 patients (10 men and 13 women, aged 43-77 years [mean, 63 years]) who later underwent surgical tumor resection. Imaging findings were retrospectively reviewed by two radiologists and were correlated with intraoperative and histologic findings. RESULTS: Helical CTAP demonstrated 33 of 35 metastases, with diameters of 4-95 mm, that were identified in resected specimens (sensitivity, 94%). The two metastases not demonstrated were 4 and 5 mm in diameter. Five false-positive lesions were found in four patients, yielding a false-positive rate of 17% by patient analysis and 13% by lesion analysis. CONCLUSION: The sensitivity of helical CTAP in the preoperative detection of hepatic metastases is high, and ifs false-positive rate compares favorably with that of conventional CTAP, but future comparative studies are needed to determine which is the better modality.
引用
收藏
页码:71 / 74
页数:4
相关论文
共 21 条
[3]   SURGICAL ANATOMY AND ANATOMICAL SURGERY OF THE LIVER [J].
BISMUTH, H .
WORLD JOURNAL OF SURGERY, 1982, 6 (01) :3-9
[4]   SPIRAL CT ARTERIAL PORTOGRAPHY OF THE LIVER [J].
BLUEMKE, DA ;
FISHMAN, EK .
RADIOLOGY, 1993, 186 (02) :576-579
[5]   DYNAMIC HEPATIC CT [J].
FOLEY, WD .
RADIOLOGY, 1989, 170 (03) :617-622
[6]   DETERMINATION OF OPTIMAL TIME WINDOW FOR LIVER SCANNING WITH CT DURING ARTERIAL PORTOGRAPHY [J].
GRAF, O ;
DOCK, WI ;
LAMMER, J ;
THURNHER, S ;
EIBENBERGER, KL ;
WILDLING, R ;
NIEDERLE, B ;
LANG, EK ;
LECHNER, G .
RADIOLOGY, 1994, 190 (01) :43-47
[7]   SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656
[8]   DETECTION OF FOCAL HEPATIC MASSES - PROSPECTIVE EVALUATION WITH CT, DELAYED CT, CT DURING ARTERIAL PORTOGRAPHY, AND MR IMAGING [J].
HEIKEN, JP ;
WEYMAN, PJ ;
LEE, JKT ;
BALFE, DM ;
PICUS, D ;
BRUNT, EM ;
FLYE, MW .
RADIOLOGY, 1989, 171 (01) :47-51
[9]   RESECTION OF THE LIVER FOR COLORECTAL-CARCINOMA METASTASES - A MULTI-INSTITUTIONAL STUDY OF LONG-TERM SURVIVORS [J].
HUGHES, KS ;
ROSENSTEIN, RB ;
SONGHORABODI, S ;
ADSON, MA ;
ILSTRUP, DM ;
FORTNER, JG ;
MACLEAN, BJ ;
FOSTER, JH ;
DALY, JM ;
FITZHERBERT, D ;
SUGARBAKER, PH ;
IWATSUKI, S ;
STARZL, T ;
RAMMING, KP ;
LONGMIRE, WP ;
OTOOLE, K ;
PETRELLI, NJ ;
HERRERA, L ;
CADY, B ;
MCDERMOTT, W ;
NIMS, T ;
ENKER, WE ;
COPPA, GF ;
BLUMGART, LH ;
BRADPIECE, H ;
URIST, M ;
ALDRETE, JS ;
SCHLAG, P ;
HOHENBERGER, P ;
STEELE, G ;
HODGSON, WJ ;
HARDY, TG ;
HARBORA, D ;
MCPHERSON, TA ;
LIM, C ;
DILLON, D ;
HAPP, R ;
RIPEPI, P ;
VILLELLA, E ;
SMITH, W ;
ROSSI, RL ;
REMINE, SG ;
OSTER, M ;
CONNOLLY, DP ;
ABRAMS, J ;
ALJURF, A ;
HOBBS, KEF ;
LI, MKW ;
HOWARD, T ;
LEE, E .
DISEASES OF THE COLON & RECTUM, 1988, 31 (01) :1-4
[10]  
IWATSUKI S, 1986, SURGERY, V100, P804