DETERMINATION OF TRUE OCTANOL WATER PARTITION-COEFFICIENTS BY MEANS OF SOLVENT GENERATED LIQUID-LIQUID CHROMATOGRAPHY

被引:10
作者
CICHNA, M [1 ]
MARKL, P [1 ]
HUBER, JFK [1 ]
机构
[1] UNIV VIENNA,INST ANALYT CHEM,A-1090 VIENNA,AUSTRIA
关键词
OCTANOL-WATER PARTITION COEFFICIENT; SOLVENT GENERATED LIQUID-LIQUID CHROMATOGRAPHY; ALKYL-BONDED SILICA; REVERSED-PHASE LIQUID CHROMATOGRAPHY; LIQUID-SOLID CHROMATOGRAPHY;
D O I
10.1016/0731-7085(95)01332-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Compared to other methods for the determination of octanol-water partition coefficients chromatography offers a number of advantages: sample purification is unnecessary, the partition coefficients of the components of a mixture can be measured simultaneously and a minimum amount of sample is needed. In the past these determinations were almost exclusively carried out by liquid-solid chromatography (LSC) on alkyl bonded silica as stationary phase (conventionally described as 'reversed-phase liquid chromatography; RPLC). Such systems based on liquid-solid distribution are, however, a poor simulation of liquid-liquid partition. On the other hand liquid-liquid chromatographic columns loaded with high amounts of water-saturated octanol are unstable since they suffer from ''column bleeding'' - a loss of the stationary liquid octanol phase caused by erosion. It is shown that the technique of solvent generated liquid-liquid chromatography (SGLLC) leads to stable columns with liquid-liquid partition as the predominant retention mechanism, if systematic errors due to specific adsorption effects are avoided by the selection of an ''inert'' solid support. This is demonstrated by the comparison of LSC and SGLLC data. SGLLC significantly reduces the scattering of the retention data of calibration standards around the calibration line. The use of SGLLC thus significantly improves the accuracy and precision of the resulting octanol-water partition coefficients.
引用
收藏
页码:339 / 351
页数:13
相关论文
共 28 条
[1]   MEASUREMENT OF LIPOPHILICITY INDEXES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - COMPARISON OF 2 STATIONARY PHASES AND VARIOUS ELUENTS [J].
BECHALANY, A ;
TSANTILIKAKOULIDOU, A ;
ELTAYAR, N ;
TESTA, B .
JOURNAL OF CHROMATOGRAPHY, 1991, 541 (1-2) :221-229
[2]   DIRECT OCTANOL WATER PARTITION-COEFFICIENT DETERMINATION USING COCURRENT CHROMATOGRAPHY [J].
BERTHOD, A ;
MENGES, RA ;
ARMSTRONG, DW .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (15-16) :2769-2785
[3]   CENTRIFUGAL PARTITION CHROMATOGRAPHY .5. OCTANOL-WATER PARTITION-COEFFICIENTS, DIRECT AND INDIRECT DETERMINATION [J].
BERTHOD, A ;
HAN, YI ;
ARMSTRONG, DW .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (07) :1441-1456
[5]   QUANTITATIVE STRUCTURE-ACTIVITY-RELATIONSHIPS FOR HERBICIDES - REVERSED-PHASE LIQUID-CHROMATOGRAPHIC RETENTION PARAMETER, LOG KW, VERSUS LIQUID-LIQUID PARTITION-COEFFICIENT AS A MODEL OF THE HYDROPHOBICITY OF PHENYLUREAS, S-TRIAZINES AND PHENOXYCARBONIC ACID-DERIVATIVES [J].
BRAUMANN, T ;
WEBER, G ;
GRIMME, LH .
JOURNAL OF CHROMATOGRAPHY, 1983, 261 (03) :329-343
[6]   DETERMINATION OF PARTITION-COEFFICIENTS BY LIQUID-CHROMATOGRAPHY [J].
CARLSON, RM ;
CARLSON, RE ;
KOPPERMAN, HL .
JOURNAL OF CHROMATOGRAPHY, 1975, 107 (01) :219-223
[7]  
CICHNA M, 1993, THESIS U VIENNA
[8]  
DOERFEL K, 1984, STATISTIK ANAL CHEM
[9]   EXTENDED OCTANOL-WATER PARTITION-COEFFICIENT DETERMINATION BY DUAL-MODE CENTRIFUGAL PARTITION CHROMATOGRAPHY [J].
GLUCK, SJ ;
MARTIN, EJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (18) :3559-3570
[10]   ESTIMATION OF AQUEOUS SOLUBILITIES OF ORGANIC NON-ELECTROLYTES USING LIQUID-CHROMATOGRAPHIC RETENTION DATA [J].
HAFKENSCHEID, TL ;
TOMLINSON, E .