IN-VIVO EVALUATION OF VISCOELASTICITY IN A BIOLOGICAL TUBE .2. APPLICATION OF A MECHANICAL MODEL

被引:1
作者
BAGI, P
THIND, P
COLSTRUP, H
机构
[1] Department of Urology, D-2111, Rigshospitalet, Copenhagen, DK-2100
关键词
COMPLIANCE; FIELD-GRADIENT PRINCIPLE; MECHANICAL MODEL; PRESSURE CROSS-SECTIONAL AREA RELATIONS; STRESS RELAXATION; URETHRA; VISCOELASTICITY;
D O I
10.1007/BF02441805
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Based on a theoretical model, the urethral stress-relaxation response following a sudden forced dilatation was studied in ten healthy female volunteers. The energy dissipation following a sudden urethral dilatation proved to follow the function Y=Z+C(alpha)e(-t/tau alpha)+C(beta)e(-t/tau beta). Hence, a mechanical model was chosen, consisting of two Maxwell elements and one Hooke element coupled in parallel. The decay in force following deformation may be described as F=F-o exp (-t.E/eta) for each Maxwell element. Thus, it was possible to determine the elastic E and viscous eta coefficients for the participating mechanical equivalents in the model, and thereby quantitatively describe the visco-elastic properties in the urethra. The reproducibility of the elastic and the viscous coefficients proved to be fairly high, and they seemed to be unaffected by the size of dilatation. On the other hand, the rate of dilatation clearly influenced the computed parameters. However, this phenomenon was easily explained by the duration of the deformation, which allowed the viscous elements to move before any measurements were performed. The present method permits in vivo evaluation of the elastic and viscous properties of the urethra, as well as other accessible biological tubes, and may be of value in the description of normal physiological and pathophysiological behaviour of the structures studied.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 24 条
[1]  
APTER JT, 1972, INVEST UROL, V9, P520
[3]   MATHEMATICAL DEVELOPMENT OF PHYSICAL MODEL OF SOME VISCO-ELASTIC PROPERTIES OF AORTA [J].
APTER, JT .
BULLETIN OF MATHEMATICAL BIOPHYSICS, 1964, 26 (04) :367-&
[4]   RELATIONSHIP BETWEEN VISCOELASTIC PROPERTIES OF RECTUM AND ANAL PRESSURE IN MAN [J].
ARHAN, P ;
FAVERDIN, C ;
PERSOZ, B ;
DEVROEDE, G ;
DUBOIS, F ;
DORNIC, C ;
PELLERIN, D .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (05) :677-682
[5]  
AXELSSON J, 1970, SMOOTH MUSCLE, P289
[6]   IN-VIVO EVALUATION OF VISCOELASTICITY IN A BIOLOGICAL TUBE .1. STRESS-RELAXATION IN THE FEMALE URETHRA STUDIED BY CROSS-SECTIONAL AREA AND PRESSURE MEASUREMENTS [J].
BAGI, P ;
THIND, P ;
COLSTRUP, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (06) :576-579
[7]   CLOSURE MECHANISM OF THE FEMALE URETHRA [J].
COLSTRUP, H .
NEUROUROLOGY AND URODYNAMICS, 1987, 6 (04) :271-298
[8]   MECHANICAL-PROPERTIES OF ARTERIES [J].
DOBRIN, PB .
PHYSIOLOGICAL REVIEWS, 1978, 58 (02) :397-460
[9]  
FUNG YC, 1981, BIOMECHANICS
[10]   ARRANGEMENTS OF COLLAGEN FIBRILS AND MUSCLE-FIBERS IN THE FEMALE URETHRA AND THEIR IMPLICATIONS FOR THE CONTROL OF MICTURITION [J].
HICKEY, DS ;
PHILLIPS, JI ;
HUKINS, DWL .
BRITISH JOURNAL OF UROLOGY, 1982, 54 (05) :556-561