NEW NONINVASIVE TRANSCUTANEOUS APPROACH TO BLOOD-GLUCOSE MONITORING - SUCCESSFUL GLUCOSE MONITORING ON HUMAN 75-G OGTT WITH NOVEL SAMPLING CHAMBER

被引:23
作者
KAYASHIMA, S
ARAI, T
KIKUCHI, M
SATO, N
NAGATA, N
TAKATANI, O
ITO, N
KIMURA, J
KURIYAMA, T
KANEYOSHI, A
机构
[1] NEC CORP LTD,CENT RES LABS,DEPT ENGN,DIV MED EQUIPMENT,KAWASAKI,KANAGAWA 213,JAPAN
[2] NATL DEF MED COLL,DEPT MED ENGN,TOKOROZAWA,SAITAMA 359,JAPAN
[3] NEC CORP LTD,CENT RES LABS,MICROELECTR RES LAB,SENSOR RES LAB,KAWASAKI,KANAGAWA 213,JAPAN
[4] NEC CORP LTD,CENT RES LABS,RESOURCES & ENVIRON PROTECT RES LABS,ENVIRON PROTECT ENGN RES LAB,KAWASAKI,KANAGAWA 213,JAPAN
关键词
D O I
10.1109/10.83587
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel noninvasive and quasi-continuous method of transcutaneous blood glucose monitoring for use with the human 75 g oral glucose tolerance test (OGTT) has been developed. The effused fluid was obtained by applying suction on the skin surface and labeled suction effusion fluid (SEF). The system consists of two main parts: a suction apparatus and the glucose sensor system. The suction apparatus applies vacuum to the patient's skin at 400 mmHg absolute pressure to collect the SEF. The miniature ion sensitive field effect transistor (ISFET) based glucose sensor can measure glucose in small SEF quantities. The monitoring system is based on the association between the glucose concentration in the SEF and in the serum. During the 75 g OGTT, the glucose change in the SEF was measured every 10 min. Although a response delay of up to 20 min was observed in the SEF glucose change, it was possible to perform the 75 g OGTT by this noninvasive monitoring method.
引用
收藏
页码:752 / 757
页数:6
相关论文
共 21 条
  • [1] ARAI T, 1987, BIOMED ENG, V25, P220
  • [2] BARTON RN, 1987, CIRC SHOCK, V22, P241
  • [3] PROTEIN CONCENTRATION AND COLLOID OSMOTIC-PRESSURE OF INTERSTITIAL FLUID COLLECTED BY WICK TECHNIQUE - ANALYSIS AND EVALUATION OF METHOD
    FADNES, HO
    AUKLAND, K
    [J]. MICROVASCULAR RESEARCH, 1977, 14 (01) : 11 - 25
  • [4] ASSESSMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION - VALIDATION OF THE WICK TECHNIQUE AS A REFERENCE FOR IMPLANTED ELECTROCHEMICAL SENSORS IN NORMAL AND DIABETIC DOGS
    FISCHER, U
    ERTLE, R
    ABEL, P
    REBRIN, K
    BRUNSTEIN, E
    VONDORSCHE, HH
    FREYSE, EJ
    [J]. DIABETOLOGIA, 1987, 30 (12) : 940 - 945
  • [5] HALJAMAE H, 1970, Microvascular Research, V2, P163, DOI 10.1016/0026-2862(70)90004-X
  • [6] CONTINUOUS TRANSCUTANEOUS OXYGEN-TENSION MEASURED WITH A HEATED ELECTRODE
    HUCH, A
    HUCH, R
    ARNER, B
    ROOTH, G
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1973, 31 (03) : 269 - 275
  • [7] A NOVEL BLOOD-GLUCOSE MONITORING METHOD AN ISFET BIOSENSOR APPLIED TO TRANS-CUTANEOUS EFFUSION FLUID
    KIMURA, J
    ITO, N
    KURIYAMA, T
    KIKUCHI, M
    ARAI, T
    NEGISHI, N
    TOMITA, Y
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (06) : 1744 - 1747
  • [8] KIMURA J, 1987, P S CHEM SENSORS, V87, P327
  • [9] LJUNGGREN L, 1986, 2ND P INT M CHEM SEN, P527
  • [10] A MICRODIALYSIS METHOD ALLOWING CHARACTERIZATION OF INTERCELLULAR WATER SPACE IN HUMANS
    LONNROTH, P
    JANSSON, PA
    SMITH, U
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (02): : E228 - E231