HEMODIALYSIS GRAFTS - COLOR DOPPLER FLOW IMAGING CORRELATED WITH DIGITAL SUBTRACTION ANGIOGRAPHY AND FUNCTIONAL STATUS

被引:61
作者
DOUSSET, V
GRENIER, N
DOUWS, C
SENUITA, P
SASSOUSTE, G
ADA, L
POTAUX, L
机构
[1] HOP PELLEGRIN, DEPT RADIOL, PL AMELIE RABA LEON, F-33076 BORDEAUX, FRANCE
[2] HOP PELLEGRIN, DEPT NEPHROL, F-33076 BORDEAUX, FRANCE
[3] HOP PELLEGRIN, DEPT VASC SURG, F-33076 BORDEAUX, FRANCE
关键词
DIALYSIS; SHUNTS; DIGITAL SUBTRACTION ANGIOGRAPHY; COMPARATIVE STUDIES; GRAFTS; STENOSIS; ULTRASOUND; (US); DOPPLER STUDIES;
D O I
10.1148/radiology.181.1.1887060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Twenty-two patients with hemodialysis grafts were prospectively evaluated with color Doppler flow imaging and digital subtraction angiography (DSA). Eighteen patients had normal functional parameters during hemodialysis, and four had increased venous pressure during hemodialysis. Color Doppler flow imaging allowed identification of nine macroaneurysms related to wall degeneration, two cases of spontaneous fistula formation between the graft and peripheral veins, and 20 stenoses. Use of color Doppler flow imaging led to overestimation of the degree of stenosis at the venous anastomosis when compared with use of angiography. Three cases of subclavian venous stenosis were identified only at angiography. Color Doppler flow imaging appears accurate in the detection of stenoses and seems sufficient for follow-up of normally functioning grafts. However, because of its low sensitivity for identification of proximal stenoses and the necessity of obtaining an angiogram to plan surgical or percutaneous correction, DSA remains the technique of choice.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 20 条
  • [1] BERARDINELLI L, 1982, ACCESS SURGERY, P99
  • [2] DIGITAL INTRAVENOUS ANGIOGRAPHY FOR THE STUDY OF HEMODIALYSIS VASCULAR ACCESS
    BURSZTYN, EM
    SHARIF, K
    BERGER, SJ
    [J]. NEPHRON, 1986, 44 (02): : 85 - 88
  • [3] THROMBOSED DIALYSIS GRAFTS - EFFICACY OF INTRATHROMBIC DEPOSITION OF CONCENTRATED UROKINASE, CLOT MACERATION, AND ANGIOPLASTY
    DAVIS, GB
    DOWD, CF
    BOOKSTEIN, JJ
    MARONEY, TP
    LANG, EV
    HALASZ, N
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (01) : 177 - 181
  • [4] FERLUGA D, 1982, ACCESS SURGERY, P121
  • [5] COLOR DOPPLER ULTRASOUND IMAGING OF LOWER-EXTREMITY VENOUS DISEASE
    FOLEY, WD
    MIDDLETON, WD
    LAWSON, TL
    ERICKSON, S
    QUIROZ, FA
    MACRANDER, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (02) : 371 - 376
  • [6] AXILLARY AND SUBCLAVIAN VEIN STENOSIS - PERCUTANEOUS ANGIOPLASTY
    GLANZ, S
    GORDON, DH
    LIPKOWITZ, GS
    BUTT, KMH
    HONG, J
    SCLAFANI, SJA
    [J]. RADIOLOGY, 1988, 168 (02) : 371 - 373
  • [7] ANGIOGRAPHY OF UPPER EXTREMITY ACCESS FISTULAS FOR DIALYSIS
    GLANZ, S
    BASHIST, B
    GORDON, DH
    BUTT, K
    ADAMSONS, R
    [J]. RADIOLOGY, 1982, 143 (01) : 45 - 52
  • [8] COLOR-FLOW DOPPLER AND CONVENTIONAL DUPLEX SCANNING OF THE CAROTID BIFURCATION - PROSPECTIVE, DOUBLE-BLIND, CORRELATIVE STUDY
    HALLAM, MJ
    REID, JM
    COOPERBERG, PL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (05) : 1101 - 1105
  • [9] IATROGENIC FEMORAL ARTERIOVENOUS-FISTULA - DIAGNOSIS WITH COLOR DOPPLER IMAGING
    IGIDBASHIAN, VN
    MITCHELL, DG
    MIDDLETON, WD
    SCHWARTZ, RA
    GOLDBERG, BB
    [J]. RADIOLOGY, 1989, 170 (03) : 749 - 752
  • [10] KEMKES BM, 1982, ACCESS SURGERY, P203