DETECTING RIGHT VENTRICULAR VOLUME CHANGES USING THE CONDUCTANCE CATHETER

被引:27
作者
WOODARD, JC
BERTRAM, CD
GOW, BS
机构
[1] UNIV NEW S WALES,CTR BIOMED ENGN,POB 1,KENSINGTON,NSW 2033,AUSTRALIA
[2] UNIV SYDNEY,DEPT PHYSIOL,SYDNEY,NSW 2006,AUSTRALIA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1992年 / 15卷 / 12期
关键词
CATHETER; CONDUCTANCE; VOLUMETRY; RIGHT VENTRICLE;
D O I
10.1111/j.1540-8159.1992.tb04172.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to assess the role of conductance catheter position within the right ventricle in obtaining adequate indications of phasic changes in ventricular volume. Possible applications of this technology are in rate responsive pacemakers and implantable defibrillators. The conductance catheter was placed in the right ventricle by cannulation of a jugular or femoral vein or a branch of the pulmonary artery. Position within the ventricle was documented from biplane fluoroscopy. Stroke volume was perturbed by: bolus injection of blood, vagal stimulation, venous infusion of methylcholine chloride, or isoprenaline. Four criteria were used to assess the quality of volume signals: (1) volume signal phase relative to the electrocardiogram; (2) magnitude parity of volume change from each electrode pair; (3) freedom from artifact; and (4) indication of stroke volume change during interventions. Greyhound dogs of either sex (n = 33), weight 20-32 kg. A total of 236 recordings from 14 distinct catheter positions were analyzed. Catheter positions originating from a femoral cannulation and one position from the pulmonary artery gave markedly superior volume transduction compared to those from the jugular route. Although right ventricular volume transduction was possible from all catheter trajectories, those resulting from the femoral approach were clearly superior. In the right ventricle, the inability to transduce a sufficient proportion of ventricular volume, in concert with the potential sensitivity of the catheter to atrial volume changes, may seriously limit the potential of the conductance technique in the applications envisaged.
引用
收藏
页码:2283 / 2294
页数:12
相关论文
共 9 条
[1]   CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[2]   CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER [J].
BAAN, J ;
JONG, TTA ;
KERKHOF, PLM ;
MOENE, RJ ;
VANDIJK, AD ;
VANDERVELDE, ET ;
KOOPS, J .
CARDIOVASCULAR RESEARCH, 1981, 15 (06) :328-334
[3]   LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE [J].
BOLTWOOD, CM ;
APPLEYARD, RF ;
GLANTZ, SA .
CIRCULATION, 1989, 80 (05) :1360-1377
[4]   ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS [J].
BURKHOFF, D ;
VANDERVELDE, E ;
KASS, D ;
BAAN, J ;
MAUGHAN, WL ;
SAGAWA, K .
CIRCULATION, 1985, 72 (02) :440-447
[5]  
Cabrera Fischer E I, 1988, Cardiovasc Res, V22, P185
[6]  
HURST JW, 1970, HEART, P76
[7]   INSTANTANEOUS MEASUREMENT OF LEFT AND RIGHT VENTRICULAR STROKE VOLUME AND PRESSURE-VOLUME RELATIONSHIPS WITH AN IMPEDANCE CATHETER [J].
MCKAY, RG ;
SPEARS, JR ;
AROESTY, JM ;
BAIM, DS ;
ROYAL, HD ;
HELLER, GV ;
LINCOLN, W ;
SALO, RW ;
BRAUNWALD, E ;
GROSSMAN, W .
CIRCULATION, 1984, 69 (04) :703-710
[8]   RIGHT VENTRICULAR VOLUMETRY BY CATHETER MEASUREMENT OF CONDUCTANCE [J].
WOODARD, JC ;
BERTRAM, CD ;
GOW, BS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04) :862-870
[9]   EFFECT OF RADIAL POSITION ON VOLUME MEASUREMENTS USING THE CONDUCTANCE CATHETER [J].
WOODARD, JC ;
BERTRAM, CD ;
GOW, BS .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (01) :25-32