COMPUTER-CONTROLLED POSITIVE DISPLACEMENT PUMP FOR PHYSIOLOGICAL FLOW SIMULATION

被引:97
作者
HOLDSWORTH, DW
RICKEY, DW
DRANGOVA, M
MILLER, DJM
FENSTER, A
机构
[1] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO M5S 1A1,ONTARIO,CANADA
[2] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON N6A 3K7,ONTARIO,CANADA
关键词
COMPUTER CONTROL; DOPPLER ULTRASOUND; FLOW SIMULATION; MAGNETIC RESONANCE; PHYSIOLOGICAL FLOW; PULSATILE PUMP;
D O I
10.1007/BF02446086
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the production of nearly uninterrupted steady flow, as well as a variety of pulsatile waveforms, including waveforms with reverse flow. The capabilities of this pump to produce steady flow from 0.1 to 60 ml s-1, as well as sinusoidal flow and physiological flow, such as that found in the common femoral and common carotid arteries are demonstrated. Cycle-to-cycle reproducibility is very good, with an average variation of 0.1 ml s-1 over thousands of cycles.
引用
收藏
页码:565 / 570
页数:6
相关论文
共 22 条
[1]  
APPUGLIESE R, 1980, 8TH CAN BIOL ENG C, P3
[2]   EXPERIMENTAL-STUDY OF PULSATILE AND STEADY FLOW THROUGH A SMOOTH TUBE AND AN ATHEROSCLEROTIC CORONARY-ARTERY CASTING OF MAN [J].
CHO, YI ;
BACK, LH ;
CRAWFORD, DW ;
CUFFEL, RF .
JOURNAL OF BIOMECHANICS, 1983, 16 (11) :933-946
[3]   ARTERIAL FLOW CHARACTERIZATION WITH A PHOTODIODE ARRAY BASED IMAGING-SYSTEM [J].
CUNNINGHAM, IA ;
YAMADA, S ;
HOBBS, BB ;
FENSTER, A .
MEDICAL PHYSICS, 1989, 16 (02) :179-187
[4]   AN INVITRO MODEL AND ITS APPLICATION FOR THE STUDY OF CAROTID DOPPLER SPECTRAL BROADENING [J].
DOUVILLE, Y ;
JOHNSTON, KW ;
KASSAM, M ;
ZUECH, P ;
COBBOLD, RSC ;
JARES, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (04) :347-356
[5]   EVALUATION OF STEADY AND PULSATILE FLOW WITH DYNAMIC MRI USING LIMITED FLIP ANGLES AND GRADIENT REFOCUSED ECHOES [J].
EVANS, AJ ;
HEDLUND, LW ;
HERFKENS, RJ ;
UTZ, JA ;
FRAM, EK ;
BLINDER, RA .
MAGNETIC RESONANCE IMAGING, 1987, 5 (06) :475-482
[6]  
FEI DY, 1988, ULTRASOUND MED BIOL, V14, P21
[7]   A COMPUTER-CONTROLLED FLOW PHANTOM FOR GENERATION OF PHYSIOLOGICAL DOPPLER WAVEFORMS [J].
HOSKINS, PR ;
ANDERSON, T ;
MCDICKEN, WN .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (11) :1709-1717
[8]  
ISSARTIER P, 1978, MED PROG TECHNOL, V6, P39
[9]  
Kiyose T, 1977, Fukuoka Igaku Zasshi, V68, P86
[10]   LASER DOPPLER ANEMOMETER MEASUREMENTS OF PULSATILE FLOW IN A MODEL CAROTID BIFURCATION [J].
KU, DN ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1987, 20 (04) :407-421