EFFECTS OF ALTERED LEFT-VENTRICULAR GEOMETRY ON QUANTITATIVE TECHNETIUM 99M SESTAMIBI DEFECT SIZE IN HUMANS - PERFUSION IMAGING DURING CORONARY ANGIOPLASTY

被引:8
作者
HARONIAN, HL
SINUSAS, AJ
REMETZ, MS
BRENNAN, JJ
CABIN, HS
ZARET, BL
WACKERS, FJT
机构
[1] YALE UNIV,SCH MED,DEPT MED,CARDIOVASC NUCL IMAGING & EXERCISE LAB,CARDIOVASC,NEW HAVEN,CT 06520
[2] YALE UNIV,SCH MED,DEPT DIAGNOST RADIOL,NUCL MED SECT,NEW HAVEN,CT 06510
关键词
TECHNETIUM 99M SESTAMIBI; VENTRICULAR GEOMETRY; PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY; ELECTROCARDIOGRAPHIC GATING;
D O I
10.1007/BF02984087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Serial myocardial perfusion imaging is used to assess exercise-induced myocardial ischemia and myocardial risk area, salvage, and viability in patients with myocardial infarction. In an experimental animal model it has beets shown that abnormal regional wall motion and altered left ventricular geometry can produce apparent perfusion defects independent of changes in blood flow. The effects of regional alteration in ventricular geometry on perfusion images in humans are not defined. The purpose of our investigation was to evaluate quantitatively the effect of altered left ventricular geometry on myocardial perfusion imaging with technetium 99m sestamibi during coronary angioplasty. Methods and Results. Nine patients with normal baseline left ventricular function referred for angioplasty of the left anterior descending coronary artery were studied. Tc-99m sestamibi was administered intravenously before angioplasty. Baseline planar electrocardiographic-gated imaging was performed. Imaging was repeated in the catheterization laboratory during angioplasty vessel occlusion when altered left ventricular geometry was produced and again later after angioplasty. Summed static, end-systolic, and end-diastolic images were generated from the electrocardiographic-gated acquisitions. Circumferential count profiles of images obtained during percutaneous transluminal coronary angioplasty (PTCA) were compared with those of a normal Tc-99m sestamibi database and their own baseline images. Defect integral (the area below the reference profile) and nadir (maximum percent decrease in activity) were derived. Compared with a normal database, new quantitative defects appeared on PTCA-summed images in only two patients. The defects were small to moderate in size. However, compared with their own baseline profile, six patients had quantitative defects during PTCA (mean defect integral 3 +/- 2; mean defect nadir 12% +/- 7%). Defect nadir was larger on end-diastolic images compared with summed images (22% +/- 7% and 12% +/- 7%, respectively; p < 0.05). Conclusions. Altered left ventricular geometry may create apparent, albeit small, planar myocardial perfusion defects in humans. Changes in defect size on serial images may be only partially caused by changes in regional wall motion or geometry.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 17 条
[1]  
CLEMAN M, 1990, CIRCULATION, V81, P14
[2]   IMPROVED MYOCARDIAL ISCHEMIC RESPONSE AND ENHANCED COLLATERAL CIRCULATION WITH LONG REPETITIVE CORONARY-OCCLUSION DURING ANGIOPLASTY - A PROSPECTIVE-STUDY [J].
CRIBIER, A ;
KORSATZ, L ;
KONING, R ;
RATH, P ;
GAMRA, H ;
STIX, G ;
MERCHANT, S ;
CHAN, C ;
LETAC, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) :578-586
[3]   EFFECTS OF MYOCARDIAL WALL THICKNESS ON SPECT QUANTIFICATION [J].
GALT, JR ;
GARCIA, EV ;
ROBBINS, WL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (02) :144-150
[4]   INFLUENCE OF LEFT-VENTRICULAR VOLUME AND WALL MOTION ON MYOCARDIAL IMAGES [J].
GEWIRTZ, H ;
GROTTE, GJ ;
STRAUSS, HW ;
OKEEFE, DD ;
AKINS, CW ;
DAGGETT, WM ;
POHOST, GM .
CIRCULATION, 1979, 59 (06) :1172-1177
[5]   VALIDATION OF CONTINUOUS RADIONUCLIDE LEFT-VENTRICULAR FUNCTIONING MONITORING IN DETECTING SILENT-MYOCARDIAL-ISCHEMIA DURING BALLOON ANGIOPLASTY OF THE LEFT ANTERIOR DESCENDING CORONARY-ARTERY [J].
KAYDEN, DS ;
REMETZ, MS ;
CABIN, HS ;
DECKELBAUM, LI ;
CLEMAN, MW ;
WACKERS, FJT ;
ZARET, BL .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (16) :1339-1343
[6]   STUNNED LEFT-VENTRICULAR MYOCARDIUM AFTER EXERCISE TREADMILL TESTING IN CORONARY-ARTERY DISEASE [J].
KLONER, RA ;
ALLEN, J ;
COX, TA ;
ZHENG, YC ;
RUIZ, CE .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (04) :329-334
[7]   PROGRESSIVE DECREASE IN MYOCARDIAL-ISCHEMIA ASSESSED BY INTRACORONARY ELECTROCARDIOGRAM DURING SUCCESSIVE AND PROLONGED CORONARY OCCLUSIONS IN ANGIOPLASTY [J].
KONING, R ;
CRIBIER, A ;
KORSATZ, L ;
STIX, G ;
CHAN, C ;
ELTCHANINOFF, H ;
LETAC, B .
AMERICAN HEART JOURNAL, 1993, 125 (01) :56-61
[8]  
MACHAC J, 1986, J NUCL MED, V27, P653
[9]  
MANTING F, 1993, J NUCL MED, V34, P601
[10]  
PELLIKKA PA, 1990, J NUCL MED, V31, P1269