IMPROVED PERFORMANCE OF CARBON-PASTE AMPEROMETRIC BIOSENSORS THROUGH THE INCORPORATION OF FUMED SILICA

被引:47
作者
WANG, J
NASER, N
机构
[1] Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces, New Mexico
关键词
FUMED SILICA; CARBON PASTE; BIOSENSOR; ENZYME ELECTRODES;
D O I
10.1002/elan.1140060707
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitivity and stability of carbon paste enzyme electrodes are greatly enhanced through the incorporation of fumed silica within the paste matrix. The improved performance is attributed to the adsorptive and electrocatalytic properties of the silica nanoparticles. The electrocatalytic action results in a substantial lowering of the overvoltage for both the oxidation and reduction of the enzymatically liberated peroxide species. Highly selective, low-potential, biosensing of glucose is thus accomplished in the presence of coexisting acetaminophen, ascorbic acid, or uric acid. The enhanced performance accrued from the presence of silica is also illustrated for mediator (dimethyl ferrocene)-containing pastes. High enzymatic activity is maintained over prolonged periods. The silica modification strategy provides an effective, fast, and inexpensive route for immobilizing enzymes within carbon paste matrices.
引用
收藏
页码:571 / 575
页数:5
相关论文
共 23 条
[1]   SILVER-COATED FUMED SILICA AS A SUBSTRATE MATERIAL FOR SURFACE-ENHANCED RAMAN-SCATTERING [J].
ALAK, AM ;
VO-DINH, T .
ANALYTICAL CHEMISTRY, 1989, 61 (07) :656-660
[2]   LONG-TERM OPERATIONAL STABILITY OF A MIXED GLUCOSE OXIDASE-REDOX MEDIATOR-CARBON PASTE ELECTRODE [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ ;
KAIFER, AE .
ANALYTICAL LETTERS, 1991, 24 (08) :1293-1315
[3]   PREPARATION AND CHARACTERIZATION OF A FRAGILE ENZYME IMMOBILIZED CARBON PASTE ELECTRODE [J].
AMINE, A ;
KAUFFMANN, JM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1992, 28 (1-2) :117-125
[4]   BIOAMPEROMETRIC SENSORS FOR PHENOL BASED ON CARBON PASTE ELECTRODES [J].
BONAKDAR, M ;
VILCHEZ, JL ;
MOTTOLA, HA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (01) :47-55
[5]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[6]   METAL-OXIDE CATALYST MEMBRANE ELECTRODES FOR THE DETERMINATION OF HYDROGEN-PEROXIDE [J].
COSGROVE, M ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1989, 114 (12) :1627-1632
[7]   A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER [J].
GORTON, L ;
KARAN, HI ;
HALE, PD ;
INAGAKI, T ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :23-30
[8]   A NEW CLASS OF AMPEROMETRIC BIOSENSOR INCORPORATING A POLYMERIC ELECTRON-TRANSFER MEDIATOR [J].
HALE, PD ;
INAGAKI, T ;
KARAN, HI ;
OKAMOTO, Y ;
SKOTHEIM, TA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (09) :3482-3484
[9]   ENZYME-MODIFIED CARBON PASTE - TETRATHIAFULVALENE ELECTRODES FOR THE DETERMINATION OF ACETYLCHOLINE [J].
HALE, PD ;
LIU, LF ;
SKOTHEIM, TA .
ELECTROANALYSIS, 1991, 3 (08) :751-756
[10]   FUMED SILICA SUBSTRATES FOR ENHANCED FLUORESCENCE SPOT-TEST ANALYSIS OF BENZO[A]PYRENE-DNA ADDUCT PRODUCTS [J].
JOHNSON, RW ;
VO-DINH, T .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2766-2769