EMISSIONS FROM A 30-KW ROTATING RETORT COMBUSTOR BURNING COKING COALS

被引:1
作者
HOWARTH, CR [1 ]
MALIK, AA [1 ]
PEHLIVAN, D [1 ]
机构
[1] FIRAT UNIV,ELAZIG,TURKEY
关键词
EMISSIONS; RETORTING; COKING COAL;
D O I
10.1016/0016-2361(93)90048-7
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A 30 kW pilot-scale rotating retort combustor was designed to burn a range of coking coals and to be capable of operating with different primary and secondary air distributions. By improving the air supply arrangements it was possible to increase the peak combustion efficiency from 80 to 95%. The NO(x) emission was in the range 61-258 ppm and was subject to the well-known temperature effect. Total hydrocarbon emission levels (C1-C-7) were significantly reduced to < 230 ppm with the improved air supply arrangements. Investigations on the effect of tilt and bed depth also showed a reduction in the C1-C-7 emission to < 15 ppm at the highest bed depth. Smoke levels were below Ringelmann 2 for all operating conditions.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 8 条
[1]  
CHEDAILLE J, 1972, IND FLAMES, V1
[2]  
COOKE MJ, 1990, ENV CONTROL B, P3
[3]  
DUNNINGHAM AC, 1938, FUEL, V17, P324
[4]  
ELLIOTT MA, 1981, CHEM COAL UTILIZATIO, pCH21
[5]  
KAVARANA BJ, 1963, THESIS U SHEFFIELD
[6]  
MALIK AA, 1992, J I ENERGY, V65, P90
[7]  
MALIK AA, 1991, THESIS U NEWCASTLE U
[8]   COLORIMETRIC MICRODETERMINATION OF NITROGEN DIOXIDE IN THE ATMOSPHERE [J].
SALTZMAN, BE .