THE ROLE OF ELECTRODE SIZE ON THE INCIDENCE OF SPREADING DEPRESSION AND ON CORTICAL CEREBRAL BLOOD-FLOW AS MEASURED BY H-2 CLEARANCE

被引:46
作者
VERHAEGEN, MJ [1 ]
TODD, MM [1 ]
WARNER, DS [1 ]
JAMES, B [1 ]
WEEKS, JB [1 ]
机构
[1] UNIV IOWA,COLL MED,DEPT ANESTHESIA,NEUROANESTHESIA RES GRP,IOWA CITY,IA 52242
关键词
CEREBRAL BLOOD FLOW; METHODOLOGY; HYDROGEN CLEARANCE; SPREADING DEPRESSION; BRAIN INJURY;
D O I
10.1038/jcbfm.1992.33
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cerebral blood flow was measured by the H-2 clearance method 30 and 60 min after the implantation of 300, 250, 125, or 50-mu-m diameter platinum-iridium electrodes 2 mm deep into the right parietal cortex of normothermic, normocarbic halothane-anesthetized rats. Another group of animals had 50-mu-m electrodes inserted 1 mm. In all animals, the presence or absence of a wave of spreading depression (SD) was noted at the time of implantation, with recordings made with glass micropipettes. H-2 flow values were compared with those measured in gray matter from the same anatomical region (but from different rats), using [H-3]nicotine. The incidence of SD ranged from 60% following insertion of 300-mu-m electrodes to 0% with 50-mu-m electrodes. H-2 clearance flows also varied with electrode size, from 77 +/- 21 ml 100 g-1 min-1 (mean +/- standard deviation) with 300-mu-m electrodes to 110 +/- 31 and 111 +/- 16 ml 100 g-1 min-1 with 125 and 50-mu-m electrodes, respectively (insertion depth of 2 mm). A CBF value of 155 +/- 60 ml 100 g-1 min-1 was obtained with 50-mu-m electrodes inserted only 1 mm. Cortical gray matter blood flow measured with [H-3]nicotine was 154 +/- 35 ml 100 g-1 min-1. When the role of SD in subsequent flow measurements was examined, there was a gradual increase in CBF between 30 and 60 min after electrode insertion in those animals with SD, while no such change was seen in rats without SD. These results indicate that the choice of electrode size and implantation depth influences the measurement of CBF by H-2 clearance. CBF values equivalent to those obtained with isotopic techniques can be acutely obtained with small (50-mu-m diameter) electrodes inserted 1 mm into the cortex. While the occurrence of SD does influence CBF in the period immediately after implantation, a relationship between electrode size and measured flow is present that is independent of SD.
引用
收藏
页码:230 / 237
页数:8
相关论文
共 23 条
[1]   MEASUREMENT OF LOCAL BLOOD FLOW WITH HYDROGEN GAS [J].
AUKLAND, K ;
BERLINER, RW ;
BOWER, BF .
CIRCULATION RESEARCH, 1964, 14 (02) :164-&
[2]   REGIONAL CEREBRAL GLUCOSE PHOSPHORYLATION AND BLOOD-FLOW AFTER INSERTION OF A MICRODIALYSIS FIBER THROUGH THE DORSAL HIPPOCAMPUS IN THE RAT [J].
BENVENISTE, H ;
DREJER, J ;
SCHOUSBOE, A ;
DIEMER, NH .
JOURNAL OF NEUROCHEMISTRY, 1987, 49 (03) :729-734
[3]  
BROCK M, 1967, EXP BRAIN RES, V4, P126
[4]  
Bures J., 1974, MECH APPL LEAOS SPRE, P26
[5]  
DRUCKOW RB, 1991, J CEREB BLOOD FLOW M, V11, P150
[6]  
FARRAR JK, 1987, CEREBRAL BLOOD FLOW, P275
[7]  
FIESCHI C, 1965, ACTA NEUROL SCAND, VS 41, P46
[8]   CEREBRAL-ISCHEMIA PRODUCED BY 4-VESSEL OCCLUSION IN THE RAT - A QUANTITATIVE-EVALUATION OF CEREBRAL BLOOD-FLOW [J].
FURLOW, TW .
STROKE, 1982, 13 (06) :852-855
[9]   EXTRACELLULAR ION CONCENTRATIONS DURING SPREADING DEPRESSION AND ISCHEMIA IN THE RAT-BRAIN CORTEX [J].
HANSEN, AJ ;
ZEUTHEN, T .
ACTA PHYSIOLOGICA SCANDINAVICA, 1981, 113 (04) :437-445
[10]   CORTICAL CELLULAR-RESPONSE IN ACUTE SUBARACHNOID HEMORRHAGE [J].
HUBSCHMANN, OR ;
KORNHAUSER, D .
JOURNAL OF NEUROSURGERY, 1980, 52 (04) :456-462