VOLUME FLOW ESTIMATION USING TIME-DOMAIN CORRELATION AND ULTRASONIC FLOWMETRY

被引:35
作者
FORSBERG, F
LIU, JB
RUSSELL, KM
GUTHRIE, SL
GOLDBERG, BB
机构
[1] THOMAS JEFFERSON UNIV,DEPT RADIOL,PHILADELPHIA,PA 19107
[2] PHILIPS ULTRASOUND,IRVINE,CA
关键词
VOLUMETRIC BLOOD FLOW MEASUREMENT; MEDICAL ULTRASOUND; SIMULATED PULSATILE WAVE-FORMS; IN VIVO CANINE FLOW MEASUREMENTS;
D O I
10.1016/0301-5629(95)00024-L
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
A comparison of two volumetric blood flow measurement techniques, CVI-Q (based on time domain correlation) and ultrasonic flowmetry, has been performed in vitro and in vivo, A pulsatile flowpump was used to simulate carotid and femoral type waveforms which were measured simultaneously using the two methods, Five dogs had their common carotid and femoral arteries exposed, and the instantaneous maximum volume flow and the mean flow were measured, Each vessel was partially occluded halfway through the experiment, simulating a 90% stenosis, In vitro, both techniques achieved absolute errors below +/-5% for flow rates over 100 mL/min, but ultrasonic flowmetry had statistically significant larger errors for slower how rates, In vivo correlation coefficients ranging from 0.73 to 0.95 were obtained with regression line slopes close to unity, The two techniques were in reasonable agreement, but with standard deviations of 20% to 28%, These studies indicate that noninvasive CVI-Q measurements of blood how in the carotid and femoral arteries are linear and accurate compared to invasive ultrasonic flowmetry.
引用
收藏
页码:1037 / 1045
页数:9
相关论文
共 21 条
[1]
AVASTHI PS, 1984, J ULTRAS MED, V3, P213
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[4]
DAUZAT M, 1989, GASTROENTEROLOGY, V96, P913
[5]
Deane CR, 1994, RADIOLOGY, V193, P232
[6]
VOLUMETRIC BLOOD-FLOW VIA TIME-DOMAIN CORRELATION - EXPERIMENTAL-VERIFICATION [J].
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :176-189
[8]
Evans D. H., 1989, DOPPLER ULTRASOUND P
[9]
THE EFFECT OF FREQUENCY-DEPENDENT SCATTERING AND ATTENUATION ON THE ESTIMATION OF BLOOD VELOCITY USING ULTRASOUND [J].
FERRARA, KW ;
ALGAZI, VR ;
LIU, JX .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (06) :754-767
[10]
FILLINGER MF, 1993, J ULTRAS MED, V12, P123