FATTY INFILTRATION OF THE LIVER - QUANTIFICATION WITH PHASE-CONTRAST MR-IMAGING AT 1.5T VS BIOPSY

被引:145
作者
LEVENSON, H
GREENSITE, F
HOEFS, J
FRILOUX, L
APPLEGATE, G
SILVA, E
KANEL, G
BUXTON, R
机构
[1] UNIV CALIF IRVINE,IRVINE MED CTR,DEPT RADIOL SCI,ROUTE 140,101 CITY DR S,ORANGE,CA 92668
[2] UNIV CALIF IRVINE,IRVINE MED CTR,DEPT MED,ORANGE,CA 92668
[3] UNIV SO CALIF,RANCHO LOS AMIGOS HOSP,DEPT PATHOL,DOWNEY,CA 90242
关键词
D O I
10.2214/ajr.156.2.1898804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantification of hepatic fat content by application of MR phase-contrast imaging (Dixon method) at 1.5 T was compared with results of biopsy in 16 patients with a variety of liver abnormalities. Motion artifact was suppressed by employing six or eight averages of short TR in-phase (echo offset, 0 msec), out-of-phase (echo offset, 1.1 msec), and in-phase (echo offset, 2.2 msec) spin-echo pulse sequences. The 360-degrees out-of-phase sequence was used to asses the impact of T2* decay on this method of estimating fat fraction. A standard two-echo long TR sequence also was obtained in all patients. Histologic preparations from the biopsy specimens were examined by a pathologist who had no knowledge of the MR results and were graded according to overall visual assessment as belonging to one of four categories of fat fraction. Results of the MR-calculated apparent fat fraction were compared directly with biopsy category and were also placed in MR fat fraction categories, allowing estimation of the statistical correlation between the biopsy and MR grading systems. Eight of eight patients with biopsy categories indicating a fat fraction of less than 0.25 were computed by MR to have a fat fraction of less than 0.1. Seven of eight patients with biopsy categories indicating a fat fraction of greater than 0.25 were computed by MR to have a fat fraction of at least 0.24. The MR-calculated apparent fat fraction category correlated significantly with the histologic biopsy category (r = .86, p < .01). When compared with the in-phase image, decreased signal from liver was visually apparent on the 180-degrees out-of-phase images in all cases in which the fat fraction was at least 0.24, but there was no indication of fatty liver on the standard T1- or T2-weighted images. Calculated T2 also showed no correlation with degree of fatty deposition. Correction for T2* decay by using the 360-degrees out-of-phase acquisition in addition to the standard 0-degrees and 180-degrees out-of-phase images had little effect on fat fraction computation. Phase-contrast MR is a promising noninvasive method for quantitative assessment of fatty deposition in the liver.
引用
收藏
页码:307 / 312
页数:6
相关论文
共 10 条
[1]   QUANTITATIVE PROTON CHEMICAL-SHIFT IMAGING [J].
AUE, WP ;
LAZEYRAS, F ;
TERRIER, F .
JOURNAL OF MAGNETIC RESONANCE, 1988, 77 (01) :160-165
[2]   CHEMICAL SHIFT-BASED TRUE WATER AND FAT IMAGES - REGIONAL PHASE CORRECTION OF MODIFIED SPIN-ECHO MR IMAGES [J].
BORRELLO, JA ;
CHENEVERT, TL ;
MEYER, CR ;
AISEN, AM ;
GLAZER, GM .
RADIOLOGY, 1987, 164 (02) :531-537
[3]   QUANTITATIVE PROTON CHEMICAL-SHIFT IMAGING [J].
BUXTON, RB ;
WISMER, GL ;
BRADY, TJ ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :881-900
[4]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[5]   INVIVO ACOUSTIC ATTENUATION IN LIVER - CORRELATIONS WITH BLOOD-TESTS AND HISTOLOGY [J].
DUERINCKX, A ;
ROSENBERG, K ;
HOEFS, J ;
AUFRICHTIG, D ;
COLEBEUGLET, C ;
KANEL, G ;
LOTTENBERG, S ;
FERRARI, LA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (05) :405-413
[6]   FATTY INFILTRATION OF THE LIVER - EVALUATION BY PROTON SPECTROSCOPIC IMAGING [J].
HEIKEN, JP ;
LEE, JKT ;
DIXON, WT .
RADIOLOGY, 1985, 157 (03) :707-710
[7]   FATTY INFILTRATION OF THE LIVER - DEMONSTRATION BY PROTON SPECTROSCOPIC IMAGING - PRELIMINARY-OBSERVATIONS [J].
LEE, JKT ;
DIXON, WT ;
LING, D ;
LEVITT, RG ;
MURPHY, WA .
RADIOLOGY, 1984, 153 (01) :195-201
[8]   FAT WATER QUANTITATION AND DIFFERENTIAL RELAXATION-TIME MEASUREMENT USING CHEMICAL-SHIFT IMAGING TECHNIQUE [J].
POON, CS ;
SZUMOWSKI, J ;
PLEWES, DB ;
ASHBY, P ;
HENKELMAN, RM .
MAGNETIC RESONANCE IMAGING, 1989, 7 (04) :369-382
[9]   HEMATOLOGIC BONE-MARROW DISORDERS - QUANTITATIVE CHEMICAL-SHIFT MR IMAGING [J].
ROSEN, BR ;
FLEMING, DM ;
KUSHNER, DC ;
ZANER, KS ;
BUXTON, RB ;
BENNET, WP ;
WISMER, GL ;
BRADY, TJ .
RADIOLOGY, 1988, 169 (03) :799-804
[10]   SUSCEPTIBILITY INDUCED MR LINE BROADENING - APPLICATIONS TO BRAIN IRON MAPPING [J].
WISMER, GL ;
BUXTON, RB ;
ROSEN, BR ;
FISEL, CR ;
OOT, RF ;
BRADY, TJ ;
DAVIS, KR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) :259-265