GADOLINIUM ENHANCED MR IMAGING OF VASCULAR STENTS

被引:37
作者
MATSUMOTO, AH
TEITELBAUM, GP
CARVLIN, MJ
BARTH, KH
SAVIN, MA
STRECKER, EP
机构
[1] GEORGETOWN UNIV HOSP, DEPT RADIOL, WASHINGTON, DC 20007 USA
[2] MEDITECH INC, WATERTOWN, MA USA
[3] DIAKONISSEN HOSP KARLSRUHE, KARLSRUHE, GERMANY
关键词
Arteries; Blood flow; Diseases; Gadolinium; Magnetic Resonance imaging; Treatment and Treatment planning; Vascular system;
D O I
10.1097/00004728-199005000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The feasibility of obtaining in-plane magnetic resonance (MR) vascular images in the presence of a vascular stent and the value of infusing an MR contrast agent during imaging was assessed. Coronal and sagittal MR imaging at 1.5 T was performed on six dogs with tantalum aortic stents using singlesection gradient echo (GRE) imaging and MR angiography techniques before and during intravenous infusion of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). In-plane gradient echo (GRE) imaging and MR angiography clearly showed flow within the stented vessel as increased signal, with a minimum amount of stent-related artifact. Infusion of Gd-DTPA significantly increased the signal of flowing blood and allowed for better delineation of the stented aortic lumina. Our results demonstrate that in-plane GRE imaging and MR angiography can potentially be used as noninvasive methods for evaluating vascular patency in the presence of MR-compatible endovascular devices. In addition, Gd-DTPA infusion during MR vascular imaging clearly enhances the definition of flowing blood in the lumina of stented vessels. © 1990 Raven Press, Ltd., New York.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 17 条
[1]  
BARTH KH, IN PRESS RADIOLOGY
[2]  
BRADLEY WG, 1988, MAGNETIC RESONANCE I, P133
[3]   SELF-EXPANDING METALLIC STENTS FOR SMALL VESSELS - AN EXPERIMENTAL EVALUATION [J].
DUPRAT, G ;
WRIGHT, KC ;
CHARNSANGAVEJ, C ;
WALLACE, S ;
GIANTURCO, C .
RADIOLOGY, 1987, 162 (02) :469-472
[4]   EFFECTS OF TURBULENCE ON SIGNAL INTENSITY IN GRADIENT ECHO IMAGES [J].
EVANS, AJ ;
BLINDER, RA ;
HERFKENS, RJ ;
SPRITZER, CE ;
KUETHE, DO ;
FRAM, EK ;
HEDLUND, LW .
INVESTIGATIVE RADIOLOGY, 1988, 23 (07) :512-518
[5]   MR VASCULAR IMAGING WITH A FAST GRADIENT REFOCUSING PULSE SEQUENCE AND REFORMATTED IMAGES FROM TRANSAXIAL SECTIONS [J].
GULLBERG, GT ;
WEHRLI, FW ;
SHIMAKAWA, A ;
SIMONS, MA .
RADIOLOGY, 1987, 165 (01) :241-246
[6]   INPLANE VASCULAR IMAGING - PULSE SEQUENCE DESIGN AND STRATEGY [J].
LENZ, GW ;
HAACKE, EM ;
MASARYK, TJ ;
LAUB, G .
RADIOLOGY, 1988, 166 (03) :875-882
[7]   TANTALUM VASCULAR STENTS - INVIVO EVALUATION WITH MR IMAGING [J].
MATSUMOTO, AH ;
TEITELBAUM, GP ;
BARTH, KH ;
CARVLIN, MJ ;
SAVIN, MA ;
STRECKER, EP .
RADIOLOGY, 1989, 170 (03) :753-755
[8]   VASCULAR MAPPING USING ALBUMIN-(GD-DTPA), AN INTRAVASCULAR MR CONTRAST AGENT, AND PROJECTION MR IMAGING [J].
MOSELEY, ME ;
WHITE, DL ;
WANG, SC ;
WIKSTROM, MG ;
DUPON, JW ;
GOBBEL, G ;
ROTH, K ;
BRASCH, RC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (02) :215-221
[9]  
OPPELT A, 1986, Electromedica (English Edition), V54, P15
[10]   EXPANDABLE INTRALUMINAL GRAFT - A PRELIMINARY-STUDY - WORK IN PROGRESS [J].
PALMAZ, JC ;
SIBBITT, RR ;
REUTER, SR ;
TIO, FO ;
RICE, WJ .
RADIOLOGY, 1985, 156 (01) :73-77