USE OF WATER AS AN INTERNAL STANDARD IN THE DIRECT MONITORING OF EMULSION POLYMERIZATION BY FIBEROPTIC RAMAN-SPECTROSCOPY

被引:45
作者
WANG, C [1 ]
VICKERS, TJ [1 ]
MANN, CK [1 ]
机构
[1] FLORIDA STATE UNIV,DEPT CHEM,TALLAHASSEE,FL 32306
关键词
EMULSION POLYMERIZATION; RAMAN SPECTROSCOPY; DIRECT ANALYSIS; METHYL METHACRYLATE; INTERNAL STANDARD;
D O I
10.1366/0003702934415183
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Direct analysis of the organic phase of an emulsion polymerization is described. Quantification uses the bending mode peak of water, which makes up the bulk of the reaction medium, as an internal standard. Although demonstrated with methyl methacrylate, the process is generally applicable to emulsion polymerizations. It does not require the introduction of an extraneous internal standard component into the reaction mixture.
引用
收藏
页码:928 / 932
页数:5
相关论文
共 4 条
  • [1] SCHRADER B, 1989, RAMAN INFRARED ATLAS
  • [2] ABSCISSA ERROR-DETECTION AND CORRECTION IN RAMAN-SPECTROSCOPY
    SHEN, CB
    VICKERS, TJ
    MANN, CK
    [J]. APPLIED SPECTROSCOPY, 1992, 46 (05) : 772 - 777
  • [3] INSITU MONITORING OF EMULSION POLYMERIZATION USING FIBEROPTIC RAMAN-SPECTROSCOPY
    WANG, C
    VICKERS, TJ
    SCHLENOFF, JB
    MANN, CK
    [J]. APPLIED SPECTROSCOPY, 1992, 46 (11) : 1729 - 1731
  • [4] Zaidel A.N., 1970, TABLES SPECTRAL LINE