SIMULATED CAPILLARY BLOOD-FLOW MEASUREMENT USING A NONLINEAR ULTRASONIC CONTRAST AGENT

被引:157
作者
SCHROPE, B
NEWHOUSE, VL
UHLENDORF, V
机构
[1] DREXEL UNIV,INST BIOMED ENGN & SCI,PHILADELPHIA,PA 19104
[2] SCHERING AG,RES LABS,INST KONTRASTMITTELFORSCH,W-1000 BERLIN 65,GERMANY
关键词
CAPILLARY BLOOD FLOW MEASUREMENT; CONTRAST AGENT; CW DOPPLER; NONLINEARITY; 2ND HARMONIC; TISSUE CLUTTER;
D O I
10.1016/0161-7346(92)90004-F
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
引用
收藏
页码:134 / 158
页数:25
相关论文
共 20 条
[1]  
BJORNO L, 1986, TISSUE CHARACTERIZAT, V1, P141
[2]   DESIGN FOR AN ULTRASOUND-BASED INSTRUMENT FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
BURNS, SM ;
REID, MH .
BIOMATERIALS ARTIFICIAL CELLS AND ARTIFICIAL ORGANS, 1989, 17 (01) :61-68
[3]  
Coakley WT, 1978, ULTRASOUND ITS APPL, P77
[4]  
DEJONG N, 1991, ULTRASONICS, V23, P324
[5]   DYNAMICS OF SKIN MICROCIRCULATION IN HUMANS [J].
FAGRELL, B .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1985, 7 :S53-S58
[6]   ULTRASONIC BACKSCATTER FROM MAMMALIAN-TISSUES [J].
FEI, DY ;
SHUNG, KK .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1985, 78 (03) :871-876
[7]   HEPATIC-TUMORS - SIGNAL ENHANCEMENT AT DOPPLER US AFTER INTRAVENOUS-INJECTION OF A CONTRAST AGENT [J].
GOLDBERG, BB ;
HILPERT, PL ;
BURNS, PN ;
LIU, JB ;
NEWMAN, LM ;
MERTON, DA ;
WITLIN, LA .
RADIOLOGY, 1990, 177 (03) :713-717
[8]   COMPREHENSIVE COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES [J].
GOSS, SA ;
JOHNSTON, RL ;
DUNN, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 64 (02) :423-457
[9]  
HARTMANN B, 1989, ENCY POLYM SCI ENG, P131
[10]  
Morse P. M., 1968, THEORETICAL ACOUSTIC, P418