FABRICATION OF POLY(CHLOROTRIFLUOROETHYLENE) PRECIOUS-METAL COMPOSITE ELECTRODES

被引:8
作者
MONTGOMERY, JB [1 ]
ANDERSON, JE [1 ]
机构
[1] MURRAY STATE UNIV,DEPT CHEM,MURRAY,KY 42071
关键词
D O I
10.1021/ac00113a054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two procedures were examined for the fabrication of poly(chlorotrifluoroethylene)/precious metal composite electrodes in an attempt to reduce the size of the active sites on the surface. A grinding procedure used with graphite was unsuccessful with platinum in that individual platinum particles became isolated from one another. As a result, the electrode material was nonconducting. A procedure which involved sputter coating the poly(chlorotrifluoroethylene) with gold prior to compression molding was successful. Electrodes fabricated with this procedure had active areas less than about 1% of their geometric area and behaved as an array of isolated ultramicroelectrodes at times less than 0.1 s.
引用
收藏
页码:3089 / 3091
页数:3
相关论文
共 13 条
[1]   ENHANCED POLY(CHLOROTRIFLUOROETHYLENE) COMPOSITE ELECTRODES [J].
ANDERSON, JE ;
MONTGOMERY, JB ;
YEE, R .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :653-656
[2]   APPARATUS FOR THE FABRICATION OF POLY(CHLOROTRIFLUOROETHYLENE) COMPOSITE ELECTRODES [J].
ANDERSON, JE ;
HOPKINS, D ;
SHADRICK, JW ;
REN, Y .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2330-2332
[3]   MICROARRAY ELECTROCHEMICAL FLOW DETECTORS AT HIGH APPLIED POTENTIALS AND LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION OF CARBAMATE PESTICIDES IN RIVER WATER [J].
ANDERSON, JL ;
WHITEN, KK ;
BREWSTER, JD ;
OU, TY ;
NONIDEZ, WK .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1366-1373
[4]   EVALUATION OF KEL-F-GRAPHITE ELECTRODES AS DETECTORS FOR CONTINUOUS-FLOW SYSTEMS [J].
CHESNEY, DJ ;
ANDERSON, JL ;
WEISSHAAR, DE ;
TALLMAN, DE .
ANALYTICA CHIMICA ACTA, 1981, 124 (02) :321-331
[5]   CALCULATION OF CONVECTIVE-DIFFUSION CURRENT AT MULTIPLE STRIP ELECTRODES IN A RECTANGULAR FLOW CHANNEL - IMPLICATIONS FOR ELECTROCHEMICAL DETECTION [J].
COPE, DK ;
TALLMAN, DE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 205 (1-2) :101-123
[6]   SILVER COMPOSITE ELECTRODE FOR VOLTAMMETRY [J].
PETERSEN, SL ;
TALLMAN, DE .
ANALYTICAL CHEMISTRY, 1988, 60 (01) :82-86
[7]   GOLD AND PLATINUM POLY(CHLOROTRIFLUOROETHYLENE) COMPOSITE ELECTRODES [J].
PETERSEN, SL ;
TALLMAN, DE .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :459-465
[8]   ON THE NATURE OF POLY(CHLOROTRIFLUOROETHYLENE) COMPOSITE ELECTRODE SURFACES [J].
PETERSEN, SL ;
WEISSHAAR, DE ;
TALLMAN, DE ;
SCHULZE, RK ;
EVANS, JF ;
DESJARLAIS, SE ;
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2385-2392
[9]   CHRONOAMPEROMETRY AT AN ENSEMBLE OF MICRODISK ELECTRODES [J].
SHOUP, D ;
SZABO, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 160 (1-2) :19-26
[10]   CARBON COMPOSITE ELECTRODES FOR LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY - OPTIMIZING DETECTOR PERFORMANCE BY TAILORING THE ELECTRODE COMPOSITION [J].
TALLMAN, DE ;
WEISSHAAR, DE .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 (12) :2157-2172