EFFECT OF MAGNETIC-SUSCEPTIBILITY CONTRAST-MEDIUM ON MYOCARDIAL SIGNAL INTENSITY WITH FAST GRADIENT-RECALLED ECHO AND SPIN-ECHO MR-IMAGING - INITIAL EXPERIENCE IN HUMANS

被引:19
作者
SAKUMA, H
OSULLIVAN, M
LUCAS, J
WENDLAND, MF
SAEED, M
DULCE, MC
WATSON, A
BLEYL, KL
LAFRANCE, ND
HIGGINS, CB
机构
[1] NYCOMED SALUTAR,SUNNYVALE,CA
[2] STERLING WINTHROP PHARMACEUT RES DIV,NEW YORK,NY
关键词
HEART; EXPERIMENTAL STUDIES; MAGNETIC RESONANCE; PULSE SEQUENCES; CONTRAST ENHANCEMENT;
D O I
10.1148/radiology.190.1.8259398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To show the effect of dysprosium diethylenetriaminepentaacetic acid bis-methylamine injection on the images of normal human myocardium. MATERIALS AND METHODS: T2-sensitive fast gradient-recalled echo (GRE) (repetition lime [TR], 10.8 msec; echo time [TE], 4.2 msec) and spin-echo (SE) (TR, three RR intervals; TE, 60 msec) magnetic resonance (MR) imaging with driven equilibrium-preparation pulse was used to produce T2 contrast material enhancement. The contrast agent was injected into 12 healthy subjects at doses of 0.05, 0.1, 0.2, 0.4, and 0.6 mmol/kg. RESULTS: Driven equilibrium-prepared GRE images showed a transient decrease of myocardial signal intensity at doses of 0.2-0.6 mmol/kg. Postcontrast T2-weighted SE images showed a myocardial signal attenuation (30%-45% decrease) at a dose of 0.4 mmol/kg or higher. CONCLUSION: Dynamic MR imaging with a magnetic susceptibility contrast medium can be used to monitor the first pass of contrast media through human myocardium with a conventional MR imager and a fast GRE sequence.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 24 条
[1]   1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING [J].
ATKINSON, DJ ;
BURSTEIN, D ;
EDELMAN, RR .
RADIOLOGY, 1990, 174 (03) :757-762
[2]  
BEEN M, 1988, BRIT HEART J, V59, P1
[3]   FUNCTIONAL CEREBRAL IMAGING BY SUSCEPTIBILITY-CONTRAST NMR [J].
BELLIVEAU, JW ;
ROSEN, BR ;
KANTOR, HL ;
RZEDZIAN, RR ;
KENNEDY, DN ;
MCKINSTRY, RC ;
VEVEA, JM ;
COHEN, MS ;
PYKETT, IL ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :538-546
[4]   REPERFUSED AND NONREPERFUSED MYOCARDIAL-INFARCTION - DIAGNOSTIC POTENTIAL OF GD-DTPA-ENHANCED MR IMAGING [J].
DEROOS, A ;
VANROSSUM, AC ;
VANDERWALL, E ;
POSTEMA, S ;
DOORNBOS, J ;
MATHEIJSSEN, N ;
VANDIJKMAN, PRM ;
VISSER, FC ;
VANVOORTHUISEN, AE .
RADIOLOGY, 1989, 172 (03) :717-720
[5]   QUANTIFICATION OF MYOCARDIAL BLOOD-FLOW AND EXTRACELLULAR VOLUMES USING A BOLUS INJECTION OF GD-DTPA - KINETIC MODELING IN CANINE ISCHEMIC DISEASE [J].
DIESBOURG, LD ;
PRATO, FS ;
WISENBERG, G ;
DROST, DJ ;
MARSHALL, TP ;
CARROLL, SE ;
ONEILL, B .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :239-253
[6]   CEREBRAL BLOOD-FLOW - ASSESSMENT WITH DYNAMIC CONTRAST-ENHANCED T2-STAR-WEIGHTED MR IMAGING AT 1.5-T [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HILL, T ;
FINN, JP ;
MAYMAN, C ;
RONTHAL, M ;
HOOGEWOUD, HM ;
KLEEFIELD, J .
RADIOLOGY, 1990, 176 (01) :211-220
[7]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[8]   FUNCTIONAL-EVALUATION OF THE HEART WITH MAGNETIC-RESONANCE IMAGING [J].
HIGGINS, CB ;
HOLT, W ;
PFLUGFELDER, P ;
SECHTEM, U .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (02) :121-139
[9]   NUCLEAR MAGNETIC-RESONANCE IMAGING OF ACUTE MYOCARDIAL-INFARCTION IN DOGS - ALTERATIONS IN MAGNETIC-RELAXATION TIMES [J].
HIGGINS, CB ;
HERFKENS, R ;
LIPTON, MJ ;
SIEVERS, R ;
SHELDON, P ;
KAUFMAN, L ;
CROOKS, LE .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (01) :184-188
[10]   1ST-PASS NUCLEAR-MAGNETIC-RESONANCE IMAGING STUDIES USING GADOLINIUM-DTPA IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
MANNING, WJ ;
ATKINSON, DJ ;
GROSSMAN, W ;
PAULIN, S ;
EDELMAN, RR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (04) :959-965