共 17 条
DETERMINATION OF GALLIUM IN PURE ALUMINUM BY ISOTOPE-DILUTION ANALYSIS WITH SOLVENT-EXTRACTION USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
被引:34
作者:
MAKISHIMA, A
[1
]
INAMOTO, I
[1
]
CHIBA, K
[1
]
机构:
[1] NIPPON STEEL CORP LTD,ANAL RES LAB,1618 IDA,KAWASAKI 211,JAPAN
关键词:
D O I:
10.1366/0003702904085840
中图分类号:
TH7 [仪器、仪表];
学科分类号:
0804 ;
080401 ;
081102 ;
摘要:
Isotope dilution analysis with inductively coupled plasma mass spectrometry (ICP-MS) was applied to the determination of gallium in pure aluminum. Furthermore, a solvent extraction procedure was combined with isotope dilution analysis as a preconcentration technique in order to determine ultra-trace levels of gallium with high precision. The accuracy and the precision of isotope dilution analysis using ICP-MS were compared with those of conventional standard addition analysis using ICP-MS. Isotope dilution analysis gave more accurate and precise results than did standard addition analysis. Isotope dilution analysis with solvent extraction made it possible to measure 0.029 μg/g gallium in 99.999% aluminum with analytical errors at less than 3%.
引用
收藏
页码:91 / 95
页数:5
相关论文