FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING

被引:80
作者
BUONOCORE, MH
BOGREN, H
机构
[1] Division of Diagnostic Radiology, University of Davis Medical Center, Sacramento, California, 95817, TICON-II Building
关键词
D O I
10.1002/mrm.1910260115
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Velocity‐encoded phase contrast imaging is being used increasingly in clinical imaging for quantization of blood flow. In this study, the accuracy and precision of ascending aorta flow measurements were found to depend on several subtle aspects of the scan prescription and image analysis. While the usual scan parameters such as TR, TE, and flip angle gave incremental changes in the flow measurements, four additional factors that had a much greater effect on the measurements were identified. These factors were (1) the zero velocity (background) pixel value, (2) the size and shape of the vessel region of interest, (3) the maximum velocity encoded in diastole, and (4) the temporal resolution. Statistical analysis was done on a total of 48 scans on nine normal subjects to confirm the significance of the measured differences using the various choices for each of these factors. These factors must be considered if accurate and precise measurements of blood flow are desired. Estimates of accuracy and precision suggest that quantitative flow measurements from velocity‐encoded MR imaging can be clinically useful. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:141 / 154
页数:14
相关论文
共 8 条
[1]   THE FUNCTION OF THE AORTA IN ISCHEMIC HEART-DISEASE - A MAGNETIC-RESONANCE AND ANGIOGRAPHIC STUDY OF AORTIC COMPLIANCE AND BLOOD-FLOW PATTERNS [J].
BOGREN, HG ;
MOHIADDIN, RH ;
KLIPSTEIN, RK ;
FIRMIN, DN ;
UNDERWOOD, RS ;
REES, SR ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 118 (02) :234-247
[2]   NORMAL FLOW PATTERNS OF INTRACRANIAL AND SPINAL CEREBROSPINAL-FLUID DEFINED WITH PHASE-CONTRAST CINE MR IMAGING [J].
ENZMANN, DR ;
PELC, NJ .
RADIOLOGY, 1991, 178 (02) :467-474
[3]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[4]  
KLIPSTEIN RH, 1987, BRIT HEART J, V58, P316
[5]   VENA-CAVAL FLOW - ASSESSMENT WITH CINE MR VELOCITY MAPPING [J].
MOHIADDIN, RH ;
WANN, SL ;
UNDERWOOD, R ;
FIRMIN, DN ;
REES, S ;
LONGMORE, DB .
RADIOLOGY, 1990, 177 (02) :537-541
[6]  
PELC NJ, 1990, VINNIE USERS GUIDE
[7]  
1988, SAS STAT USERS GUIDE, P283
[8]  
[No title captured]