ONLINE INTRAOPERATIVE QUANTITATION OF REGIONAL MYOCARDIAL PERFUSION DURING CORONARY-ARTERY BYPASS GRAFT OPERATIONS WITH MYOCARDIAL CONTRAST 2-DIMENSIONAL ECHOCARDIOGRAPHY

被引:42
作者
VILLANEUVA, FS
SPOTNITZ, WD
JAYAWEERA, AR
DENT, J
GIMPLE, LW
KAUL, S
机构
[1] UNIV VIRGINIA,SCH MED,DEPT INTERNAL MED,DIV CARDIOL,BOX 158,CHARLOTTESVILLE,VA 22908
[2] UNIV VIRGINIA,SCH MED,DEPT SURG,DIV THORAC & CARDIOVASC SURG,CHARLOTTESVILLE,VA 22908
关键词
D O I
10.1016/S0022-5223(19)33879-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We hypothesized that the success of coronary artery bypass graft operations could be assessed by means of on-line quantitative myocardial contrast echocardiography. Accordingly, myocardial contrast echocardiography was performed at baseline and after each placement of venous graft in 21 patients undergoing coronary artery bypass graft operations. Time-intensity plots were generated on-line with the use of a dedicated computer system, and areas under the curve were assessed for each injection. Successful on-line quantitation of myocardial contrast echocardiography data was performed in 17 patients; this allowed comparison before and after coronary artery bypass graft operations for 21 grafts, with agreement between expert visual analysis and quantitative data in 91 % of these cases. Three distinct perfusion patterns were noted on myocardial contrast echocardiography: (1) reduced contrast effect before coronary artery bypass graft operations with improvement after coronary artery bypass graft operations (n = 11), (2) adequate contrast effect before coronary artery bypass graft operations with no change after coronary artery bypass graft operations (n = 9) (for patients in group 2, the mean percentage of coronary stenosis was less than the mean for patients in group 1-67% +/- 25 % vs. 88 % +/- 20 %, p = 0.05); and (3) no contrast effect either before or after coronary artery bypass graft operations in one patient with previous infarction. One third of the time (34 of 95 injections), on-line quantitation was unsuccessful. Failure was related three times more often to problems associated with myocardial contrast echocardiography, such as attenuation and inadequate quality of bubbles, than to computer failure. Despite its limitations, on-line quantitative myocardial contrast echocardiography is feasible in patients undergoing coronary artery bypass graft operations and provides important objective information regarding the success of revascularization.
引用
收藏
页码:1524 / 1531
页数:8
相关论文
共 27 条
[1]   CONTRAST ECHOCARDIOGRAPHY - A METHOD TO VISUALIZE CHANGES IN REGIONAL MYOCARDIAL PERFUSION IN THE DOG-MODEL FOR CABG SURGERY [J].
ARONSON, S ;
BENDER, E ;
FEINSTEIN, SB ;
HEIDENREICH, PH ;
ELLIS, J ;
DICK, C ;
ROIZEN, MF ;
KARP, RB .
ANESTHESIOLOGY, 1990, 72 (02) :295-301
[2]   ASSESSMENT OF MYOCARDIAL PERFUSION DURING CABG SURGERY WITH 2-DIMENSIONAL TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY [J].
ARONSON, S ;
LEE, BK ;
WIENCEK, JG ;
FEINSTEIN, SB ;
ROIZEN, MF ;
KARP, RB ;
ELLIS, JE .
ANESTHESIOLOGY, 1991, 75 (03) :433-440
[3]   HYPOXEMIA AND CORONARY BLOOD FLOW [J].
BERNE, RM ;
BLACKMON, JR ;
GARDNER, TH .
JOURNAL OF CLINICAL INVESTIGATION, 1957, 36 (07) :1101-1106
[4]   MYOCARDIAL-INFARCTION DETERMINED BY TECHNETIUM-99M PYROPHOSPHATE SINGLE-PHOTON TOMOGRAPHY COMPLICATING ELECTIVE CORONARY-ARTERY BYPASS-GRAFTING FOR ANGINA-PECTORIS [J].
BURNS, RJ ;
GLADSTONE, PJ ;
TREMBLAY, PC ;
FEINDEL, CM ;
SALTER, DR ;
LIPTON, IH ;
OGILVIE, RR ;
DAVID, TE .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (20) :1429-1434
[5]   QUANTITATIVE TWO-DIMENSIONAL ECHOCARDIOGRAPHIC ANALYSIS OF REGIONAL WALL MOTION IN PATIENTS WITH PERIOPERATIVE MYOCARDIAL-INFARCTION [J].
FORCE, T ;
BLOOMFIELD, P ;
OBOYLE, JE ;
KHURI, SF ;
JOSA, M ;
PARISI, AF .
CIRCULATION, 1984, 70 (02) :233-241
[6]   INTRAOPERATIVE CARDIOPLEGIC CONTRAST ECHOCARDIOGRAPHY FOR ASSESSING MYOCARDIAL PERFUSION DURING OPEN-HEART SURGERY [J].
GOLDMAN, ME ;
MINDICH, BP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (05) :1029-1034
[7]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[8]  
GRONDIN CM, 1981, J THORAC CARDIOV SUR, V82, P608
[9]   INADEQUATE CARDIOPLEGIC PROTECTION WITH OBSTRUCTED CORONARY-ARTERIES [J].
HILTON, CJ ;
TEUBL, W ;
ACKER, M ;
LEVINSON, HJ ;
MILLARD, RW ;
RIDDLE, R ;
MCENANY, MT .
ANNALS OF THORACIC SURGERY, 1979, 28 (04) :323-334
[10]  
Jayaweera A R, 1990, J Am Soc Echocardiogr, V3, P91