FEASIBILITY OF RECANALIZATION OF HUMAN CORONARY-ARTERIES USING HIGH-INTENSITY ULTRASOUND

被引:15
作者
ERNST, A [1 ]
SCHENK, EA [1 ]
WOODLOCK, TJ [1 ]
ALLIGER, H [1 ]
GOTTLIEB, S [1 ]
CHILD, SZ [1 ]
MELTZER, RS [1 ]
机构
[1] UNIV ROCHESTER, MED CTR, BOX 679, ROCHESTER, NY 14642 USA
关键词
D O I
10.1016/0002-9149(94)90202-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To investigate the feasibility of ultrasonic recanalization of obstructed human coronary arteries in vitro, high-intensity ultrasound was applied to 16 coronary arteries obtained at autopsy, using a prototype instrument enabling insonification through a catheter tip. It was 119 cm long, 0.95 mm thick wire in an 8Fr catheter connected to an external ultrasonic transformer and power generator. A 5 MHz phased-array 2-dimensional echocardiography instrument was used to determine minimal luminal diameter and percent diameter narrowing before and after ultrasound application. The ultrasonic energy was delivered at 21.5 kHz and with a 52 +/- 19 mum average amplitude of tip displacement. The mean percent luminal diameter narrowing, flow rate and mean pressure gradient before ultrasound exposure were 74 +/- 11%, 97 +/- 61 ml/min, and 92 +/- 18 mm Hg, respectively. After recanalization, the mean percent luminal diameter narrowing decreased to 45 +/- 17% (p < 0.001), the mean flow rate increased to 84 +/- 92 ml/min (p < 0.001), and the mean pressure gradient was reduced to 45 +/- 24 mm Hg (p < 0.001). Of the debris particles, 95% had a diameter <9 mum (range 5 to 12). Arterial perforation occurred in 5 of 16 arteries (31%) and all 5 occurred due to stiff wire manipulation and without ultrasound application. Mechanical fracture of the wire occurred in 8 cases (50%). No signs of thermal injury were found on histology. Thus, ultrasonic recanalization of human coronary arteries in vitro is feasible. It may reduce obstruction and improve blood flow. Debris sizes are sufficiently small to minimize the hazard of peripheral embolization.
引用
收藏
页码:126 / 132
页数:7
相关论文
共 20 条
[1]  
Alliger H., 1975, American Laboratory, V7, P75
[2]   ULTRASONIC DECALCIFICATION OF CALCIFIED CARDIAC VALVES AND ANNULI [J].
BROWN, AH ;
DAVIES, PGH .
BRITISH MEDICAL JOURNAL, 1972, 3 (5821) :274-&
[3]   HIGH-INTENSITY ULTRASOUND INCREASES DISTENSIBILITY OF CALCIFIC ATHEROSCLEROTIC ARTERIES [J].
DEMER, LL ;
ARIANI, M ;
SIEGEL, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (05) :1259-1262
[4]   ABILITY OF HIGH-INTENSITY ULTRASOUND TO ABLATE HUMAN ATHEROSCLEROTIC PLAQUES AND MINIMIZE DEBRIS SIZE [J].
ERNST, A ;
SCHENK, EA ;
GRACEWSKI, SM ;
WOODLOCK, TJ ;
MURANT, FG ;
ALLIGER, H ;
MELTZER, RS .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (02) :242-246
[5]   INTERACTION MECHANISM BETWEEN CAVITATION BUBBLES AND PARTICLES OF SOLID AND LIQUID-PHASES [J].
FRIDMAN, VM .
ULTRASONICS, 1972, 10 (04) :162-&
[6]  
Frizzell L.A., 1988, P287
[7]   ULTRASONIC CLOT DISRUPTION - AN INVITRO STUDY [J].
HONG, AS ;
CHAE, JS ;
DUBIN, SB ;
LEE, S ;
FISHBEIN, MC ;
SIEGEL, RJ .
AMERICAN HEART JOURNAL, 1990, 120 (02) :418-422
[8]   INTRAVASCULAR DELIVERY OF LASER ENERGY WITH METAL-CAPPED OPTICAL FIBERS - THE POTENTIAL HAZARD OF DISTAL EMBOLISM [J].
KEOGH, BE ;
CREA, F ;
BULL, T ;
BLACKIE, RAS ;
TAYLOR, KM .
AMERICAN HEART JOURNAL, 1989, 118 (01) :47-53
[9]   EXPERIMENTAL ULTRASONIC ANGIOPLASTY - DISRUPTION OF ATHEROSCLEROTIC PLAQUES AND THROMBI INVITRO AND ARTERIAL RECANALIZATION INVIVO [J].
ROSENSCHEIN, U ;
BERNSTEIN, JJ ;
DISEGNI, E ;
KAPLINSKY, E ;
BERNHEIM, J ;
ROZENZSAJN, LA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (03) :711-717
[10]  
SEGEL GB, 1981, BLOOD, V57, P894