CINE GRADIENT REFOCUSED ECHO (GRE) IMAGING OF INTRAVASCULAR MASSES - DIFFERENTIATION BETWEEN TUMOR AND NONTUMOR THROMBUS

被引:22
作者
SEELOS, KC
CAPUTO, GR
CARROL, CL
HRICAK, H
HIGGINS, CB
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,BOX 0628,SAN FRANCISCO,CA 94143
[2] ST LUKES HOSP,DEPT RADIOL,HOUSTON,TX
[3] TEXAS CHILDRENS HOSP,HOUSTON,TX 77030
[4] TEXAS HEART INST,HOUSTON,TX 77025
关键词
MAGNETIC RESONANCE IMAGING; GRADIENT REFOCUSED ECHO (GRE) TECHNIQUE; VASCULAR SYSTEM; NEOPLASMS;
D O I
10.1097/00004728-199203000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spin echo MR imaging has not permitted reliable differentiation between intraluminal blood clot and tumor thrombus. This study assessed the role of ECG referenced repetitive gradient refocused echo (cine GRE) imaging for the differentiation of intravascular tumor from blood clot. Cine GRE images were reviewed in 23 patients, 11 of whom had intravascular tumor and 12 of whom had intravascular blood clots. Percentage contrast between the lesion and skeletal muscle as the reference tissue was determined from a subjective review of the images and objective signal intensity measurements. Intravascular clots were found to be lower in signal intensity than muscle (mean -55 +/- 29%). Intravascular tumors showed higher signal intensity relative to muscle (mean + 17 +/- 9%) with the exception of myxomas (n = 2), which had signal intensity values relative to muscle as low as clots (mean -41 +/- 17%). Three masses in the inferior vena cava were composed of central tumor and peripheral clot; the two components could be differentiated with cine GRE imaging. Cine GRE imaging provides adequate signal intensity differences to visualize intravascular masses and helps to differentiate intravascular clot from tumor thrombus. However, if the tumor contains substantial amounts of iron, then the signal is also low and consequently clot and thrombus may not be distinguishable. This can occur in some atrial myxomas.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 18 条
[1]  
ANGLADE MC, 1989, DIAGN INTERV RADIOL, V1, P61
[2]   MAGNETIC-RESONANCE VELOCITY MAPPING IN AORTIC DISSECTION [J].
BOGREN, HG ;
UNDERWOOD, SR ;
FIRMIN, DN ;
MOHIADDIN, RH ;
KLIPSTEIN, RH ;
REES, RSO ;
LONGMORE, DB .
BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726) :456-462
[3]   EVALUATION OF STEADY AND PULSATILE FLOW WITH DYNAMIC MRI USING LIMITED FLIP ANGLES AND GRADIENT REFOCUSED ECHOES [J].
EVANS, AJ ;
HEDLUND, LW ;
HERFKENS, RJ ;
UTZ, JA ;
FRAM, EK ;
BLINDER, RA .
MAGNETIC RESONANCE IMAGING, 1987, 5 (06) :475-482
[4]   THE CONTRIBUTION OF MAGNETIC-RESONANCE IMAGING TO THE EVALUATION OF INTRACARDIAC TUMORS DIAGNOSED BY ECHOCARDIOGRAPHY [J].
FREEDBERG, RS ;
KRONZON, I ;
RUMANCIK, WM ;
LIEBESKIND, D .
CIRCULATION, 1988, 77 (01) :96-103
[5]   CARDIAC TUMORS AND THROMBUS - EVALUATION WITH MR IMAGING [J].
GOMES, AS ;
LOIS, JF ;
CHILD, JS ;
BROWN, K ;
BATRA, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (05) :895-899
[6]  
GOMORI JM, 1988, RADIOGRAPHICS, V8, P124
[7]   ABDOMINAL VENOUS SYSTEM - ASSESSMENT USING MR [J].
HRICAK, H ;
AMPARO, E ;
FISHER, MR ;
CROOKS, L ;
HIGGINS, CB .
RADIOLOGY, 1985, 156 (02) :415-422
[8]   MR IMAGING OF PORTAL-VEIN THROMBOSIS [J].
LEVY, HM ;
NEWHOUSE, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (02) :283-286
[9]  
LIE JT, 1989, ARCH PATHOL LAB MED, V113, P742
[10]   CINE GRADIENT-REFOCUSED MR IMAGING OF CENTRAL PULMONARY EMBOLI [J].
POSTERARO, RH ;
SOSTMAN, HD ;
SPRITZER, CE ;
HERFKENS, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :465-468