INTRACARDIAC ECHOCARDIOGRAPHY DURING RADIOFREQUENCY CATHETER ABLATION OF CARDIAC-ARRHYTHMIAS IN HUMANS

被引:117
作者
CHU, E
KALMAN, JM
KWASMAN, MA
JUE, JCY
FITZGERALD, PJ
EPSTEIN, LM
SCHILLER, NB
YOCK, PG
LESH, MD
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT MED,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,INST CARDIOVASC RES,SAN FRANCISCO,CA 94143
关键词
D O I
10.1016/0735-1097(94)90119-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to describe our reliminary experience using catheter based intracardiac echocardiography as an adjunct to biplane fluoroscopy for guiding radiofrequency catheter ablation of atrial arrhythmias in the right side of the heart. Background. Catheter ablation requires precise positioning and stable ablation electrode-endocardial contact. This procedure is currently guided by an analysis of intracardiac electrograms and fluoroscopy. However, the use of fluoroscopy does not allow the endocardium and certain anatomic landmarks to be identified and is associated with the hazards of radiation exposure. Methods. Seventeen symptomatic patients were studied. A 10F 10-MHz intracardiac imaging catheter was used to visualize specific anatomic landmarks in the right atrium for directing the ablation electrode in 15 patients undergoing radiofrequency ablation of 19 arrhythmias and to assist with interatrial septal puncture in 3 patients. Results. Continuous intracardiac imaging was performed for a mean +/- SD of 63.6 +/- 39.2 min and demonstrated distal electrode-endocardial tissue contact in 81 (60%) of 134 radiofrequency applications. Movement of the catheter was demonstrated during 36 (44%), microcavitations during 39 (48%) and thrombus during 15 (19%) of the 81 imaged applications. In 7 of 10 procedures for atrial flutter, successful ablation was directed at anatomic corridors in the right atrium visualized with intracardiac echocardiography. During ablation of atrial tachycardia, imaging identified abnormal atrial anatomy related to previous surgery and guided successful ablation of a reentrant tachycardia circulating around these anatomic obstacles. In two procedures for slow pathway modification of atrioventricular node reentrant tachycardia, in tracardiac echocardiography confirmed catheter stability at the tricuspid annulus anterior to the coronary sinus. Conclusions. During catheter ablation, intracardiac echocardiography augments fluoroscopy by visualizing anatomic landmarks, ensuring stable endocardial contact and assisting in transseptal puncture. Ablation of typical atrial butter can be successfully directed at anatomic corridors identified using intracardiac imaging.
引用
收藏
页码:1351 / 1357
页数:7
相关论文
共 25 条
  • [1] RADIATION EXPOSURE DURING RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY ATRIOVENTRICULAR CONNECTIONS
    CALKINS, H
    NIKLASON, L
    SOUSA, J
    ELATASSI, R
    LANGBERG, J
    MORADY, F
    [J]. CIRCULATION, 1991, 84 (06) : 2376 - 2382
  • [2] DIAGNOSIS AND CURE OF THE WOLFF-PARKINSON-WHITE SYNDROME OR PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIAS DURING A SINGLE ELECTROPHYSIOLOGIC TEST
    CALKINS, H
    SOUSA, J
    ELATASSI, R
    ROSENHECK, S
    DEBUITLEIR, M
    KOU, WH
    KADISH, AH
    LANGBERG, JJ
    MORADY, F
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (23) : 1612 - 1618
  • [3] RADIOFREQUENCY CATHETER ABLATION GUIDED BY INTRACARDIAC ECHOCARDIOGRAPHY
    CHU, E
    FITZPATRICK, AP
    CHIN, MC
    SUDHIR, K
    YOCK, PG
    LESH, MD
    [J]. CIRCULATION, 1994, 89 (03) : 1301 - 1305
  • [4] CIKES I, 1989, ECHOCARDIOGRAPHY CAR, P77
  • [5] RADIOFREQUENCY ABLATION OF THE INFERIOR VENA-CAVA - TRICUSPID-VALVE ISTHMUS IN COMMON ATRIAL-FLUTTER
    COSIO, FG
    LOPEZGIL, M
    GOICOLEA, A
    ARRIBAS, F
    BARROSO, JL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (08) : 705 - 709
  • [6] FRAGMENTED ELECTROGRAMS AND CONTINUOUS ELECTRICAL-ACTIVITY IN ATRIAL-FLUTTER
    COSIO, FG
    ARRIBAS, F
    PALACIOS, J
    TASCON, J
    LOPEZGIL, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (15) : 1309 - 1314
  • [7] ACCURACY OF VARIOUS METHODS OF LOCALIZATION OF THE ORIFICE OF THE CORONARY SINUS AT ELECTROPHYSIOLOGIC STUDY
    DAVIS, LM
    BYTH, K
    LAU, KC
    UTHER, JB
    RICHARDS, DAB
    ROSS, DL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (03) : 343 - 346
  • [8] EVIDENCE OF A REENTRY CIRCUIT IN THE COMMON TYPE OF ATRIAL-FLUTTER IN MAN
    DISERTORI, M
    INAMA, G
    VERGARA, G
    GUARNERIO, M
    DELFAVERO, A
    FURLANELLO, F
    [J]. CIRCULATION, 1983, 67 (02) : 434 - 440
  • [9] RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES
    FELD, GK
    FLECK, RP
    CHEN, PS
    BOYCE, K
    BAHNSON, TD
    STEIN, JB
    CALISI, CM
    IBARRA, M
    [J]. CIRCULATION, 1992, 86 (04) : 1233 - 1240
  • [10] TRANSESOPHAGEAL ECHOCARDIOGRAPHY TO IMPROVE POSITIONING OF RADIOFREQUENCY ABLATION CATHETERS IN LEFT-SIDED WOLFF-PARKINSON-WHITE SYNDROME
    GOLDMAN, AP
    IRWIN, JM
    GLOVER, MU
    MICK, W
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (08): : 1245 - 1250