RELATION BETWEEN TRANSCARDIAC AND TRANSTHORACIC CURRENT DURING DEFIBRILLATION IN HUMANS

被引:98
作者
LERMAN, BB [1 ]
DEALE, OC [1 ]
机构
[1] UNIV VIRGINIA, HLTH SCI CTR, DEPT MED, DIV CARDIOL, CHARLOTTESVILLE, VA 22903 USA
关键词
Arrhythmia; Automatic implantable defibrillator; Ventricular fibrillation;
D O I
10.1161/01.RES.67.6.1420
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Conceptually, transthoracic defibrillation threshold current can be considered a function of at least two quantities. It is directly proportional to the transcardiac threshold current and inversely proportional to the transcardiac current fraction (F(C)) or the ratio of transcardiac and transthoracic current. Although experimental and theoretical estimates of F(C) have been as high as 45%, previous measurements in humans have not been made. This study was designed to quantify F(C) in humans. During intraoperative testing of the automatic implantable cardioverter defibrillator, transthoracic rescue shocks of 200-400 J were delivered when the device failed to defibrillate. Simultaneous transthoracic voltage (V(T)) and transcardiac voltage (V(C)) between two implanted epicardial patch electrodes were measured. The ratio, V(C)/V(T), was 0.04 ± 0.03 (mean ± SD) in 10 patients. In 16 dogs, a comparison was made between direct measurement of F(C) and V(C)/V(T). F(C) was determined with a specially designed electrode system, which was calibrated to account for field distortion introduced by the electrodes. There was no significant difference between F(C) and V(C)/V(T), which were both approximately 0.05, suggesting that V(C)/V(T) was statistically equivalent to F(C). The results of this study, therefore, indicate that during transthoracic defibrillation in humans, approximately 4% of transthoracic current traverses the heart. This relatively small percentage of current results from the existence of parallel pathways, such as the thoracic cage and lungs, which shunt current around the heart.
引用
收藏
页码:1420 / 1426
页数:7
相关论文
共 17 条
[1]   CHANGES IN BODYS QRS SURFACE POTENTIALS PRODUCED BY ALTERATIONS IN CERTAIN COMPARTMENTS OF NONHOMOGENEOUS CONDUCTING MODEL [J].
BAYLEY, RH ;
KALBFLEISCH, JM ;
BERRY, PM .
AMERICAN HEART JOURNAL, 1969, 77 (04) :517-+
[2]   OPTIMAL ELECTRODE CONFIGURATIONS FOR EXTERNAL CARDIAC PACING AND DEFIBRILLATION - AN INHOMOGENEOUS STUDY [J].
BENFAHY, J ;
KIM, YM ;
ANANTHASWAMY, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (09) :743-748
[3]   COMPARISON OF THE DEFIBRILLATION THRESHOLD AND THE UPPER LIMIT OF VENTRICULAR VULNERABILITY [J].
CHEN, PS ;
SHIBATA, N ;
DIXON, EG ;
MARTIN, RO ;
IDEKER, RE .
CIRCULATION, 1986, 73 (05) :1022-1028
[4]   A VOLUME CONDUCTOR MODEL OF THE THORAX FOR THE STUDY OF DEFIBRILLATION FIELDS [J].
CLAYDON, FJ ;
PILKINGTON, TC ;
TANG, ASL ;
MORROW, MN ;
IDEKER, RE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (11) :981-992
[5]   INTRATHORACIC CURRENT FLOW DURING TRANSTHORACIC DEFIBRILLATION IN DOGS - TRANSCARDIAC CURRENT FRACTION [J].
DEALE, OC ;
LERMAN, BB .
CIRCULATION RESEARCH, 1990, 67 (06) :1405-1419
[6]   FACTORS CONCERNED IN ELECTRICAL DEFIBRILLATION OF THE HEART, PARTICULARLY THROUGH THE UNOPENED CHEST [J].
GUYTON, AC ;
SATTERFIELD, J .
AMERICAN JOURNAL OF PHYSIOLOGY, 1951, 167 (01) :81-87
[7]   A through type current transformer and amplifier for measuring alternating currents of a few milliamperes [J].
Kouwenhoven, WB .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1931, 2 (09) :541-548
[8]   The current flowing through the heart under conditions of electric shock [J].
Kouwenhoven, WB ;
Hooker, DR ;
Langworthy, OR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1932, 100 (02) :344-350
[9]  
Kouwenhoven WB, 1933, ELECTRON ENG, V52, P475
[10]   EFFECT OF EPICARDIAL PATCH ELECTRODES ON TRANSTHORACIC DEFIBRILLATION [J].
LERMAN, BB ;
DEALE, OC .
CIRCULATION, 1990, 81 (04) :1409-1414