2 NEW ALGORITHMS FOR TRACKING ARTERIAL PARAMETERS IN NONSTATIONARY NOISE CONDITIONS

被引:4
作者
AVANZOLINI, G [1 ]
BARBINI, P [1 ]
CAPPELLO, A [1 ]
CEVENINI, G [1 ]
机构
[1] UNIV SIENA,IST CHIRURG TORAC & CARDIOVASC,SEZ BIOINGN,I-53100 SIENA,ITALY
关键词
D O I
10.1109/10.364519
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two new algorithms with reduced sensitivity to the changing environment are applied to tracking arterial circulation parameters, They are variants of the Least-Squares (LS) algorithm with Variable Forgetting factor (LSVF), and of the Constant Forgetting factor-Covariance Modification (CFCM) LS algorithm, devised to overcome their main practical deficiencies related to noise level sensitivity and the high number of design variables, respectively, To this end, adaptive mechanisms are incorporated to estimate observation noise variance in LSVP and the rate of change for the different parameters in CFCM, Specific computer simulation experiments are presented to compare their effectiveness with the original counterparts and to provide guidelines for their optimal tuning at different noise levels, Moreover, algorithm performance degradation, consequent on changes in the noise level compared to that assumed during the tuning phase, is analyzed, In particular, it is shown that, when the noise level changes with respect to the tuning value, the new LSVF algorithm is much more robust than the original one, whose performance degrades rapidly, The new CFCM algorithm is characterized by a reduced number of design variables with respect to its original counterpart, Nevertheless, it can be preferred only when low noise signals are used for estimation.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 11 条
[1]   COMPARISON OF ALGORITHMS FOR TRACKING SHORT-TERM CHANGES IN ARTERIAL CIRCULATION PARAMETERS [J].
AVANZOLINI, G ;
BARBINI, P ;
CAPPELLO, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (08) :861-867
[2]  
AVANZOLINI G, 1984, Automedica (London), V5, P37
[3]   ESTIMATION TECHNIQUE FOR TRACKING RAPID PARAMETER CHANGES [J].
CHEN, MJ ;
NORTON, JP .
INTERNATIONAL JOURNAL OF CONTROL, 1987, 45 (04) :1387-1398
[4]   FEASIBILITY OF CLOSED-LOOP CONTROL OF INTRA-AORTIC BALLOON PUMPING [J].
CLARK, JW ;
KANE, GR ;
BOURLAND, HM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (06) :404-412
[5]   AUTOMATIC-CONTROL OF A SERIES-PARALLEL MECHANICAL CIRCULATORY ASSIST SYSTEM IN SEVERE UNIVENTRICULAR OR BIVENTRICULAR FAILURE [J].
CLARK, JW ;
PHILIPPE, E ;
PETERSON, R ;
LANDE, A ;
ELLIS, JR .
ANNALS OF BIOMEDICAL ENGINEERING, 1980, 8 (01) :57-74
[7]   IMPLEMENTATION OF SELF-TUNING REGULATORS WITH VARIABLE FORGETTING FACTORS [J].
FORTESCUE, TR ;
KERSHENBAUM, LS ;
YDSTIE, BE .
AUTOMATICA, 1981, 17 (06) :831-835
[8]  
Goodwin GC, 1984, ADAPTIVE FILTERING P
[10]  
Ljung L, 1983, THEORY PRACTICE RECU