EVALUATION OF A TECHNIQUE FOR THE QUANTIFICATION OF RADIOACTIVITY AND VOLUME OF AN OBJECT USING SPECT

被引:17
作者
ALAAMER, AS [1 ]
FLEMING, JS [1 ]
PERRING, S [1 ]
机构
[1] SOUTHAMPTON GEN HOSP,DEPT NUCL MED,SOUTHAMPTON SO9 4XY,HANTS,ENGLAND
关键词
D O I
10.1097/00006231-199312000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The technique of threshold determination using maximization of interclass variance (MIV) has been evaluated for the assessment of radioactivity and Volume in single photon emission computed tomography (SPECT). The SPECT reconstruction incorporated scatter and attenuation correction using an attenuation map from computed tomographic (CT) images. The technique has been examined on a large number of phantom objects with both Tc-99(m) and I-131. Volume measurement of objects was performed using a variety of methods of applying the MTV technique. The standard error of volume estimation for the optimum method was 7.3 ml for Tc-99(m) and 15.3 ml for I-131. Activity was measured by expansion of the volume of interest representing the space occupied by the object to make allowance for limited SPECT resolution. The standard errors of the activity measurements were 0.22 MBQ for Tc-99(m) and 0.24 MBq for I-131.
引用
收藏
页码:1061 / 1070
页数:10
相关论文
共 30 条
[1]  
Szur L., Glass H.I., Lewis S.M., Grammatcios P., De Garreta A.C., Quantitative estimation of red-cell uptake in the spleen using 81 Rb- and 51Cr-labelled red cells, Br J Radiol, 41, pp. 819-825, (1968)
[2]  
Arimizu N., Kakehi H., Morris A.C., Quantitative measurement of radioactivity in internal organs by area scanning, J Nucl Med, 10, pp. 265-269, (1969)
[3]  
Glass H., Williams W., Arnold R., A dual detector scanner for quantitative uptake and organ volume studies, Medical Radiosotope Scintigraphy, (1969)
[4]  
Sorenson J.A., Quantitation of radioactive content in vivo using combined emission-transmission measurements, J Nucl Med, 11, (1970)
[5]  
Clarke L.P., Laughlin J.W., Klaus M., Quantitative organ- uptake measurement, Radiology, 102, pp. 375-383, (1972)
[6]  
Budinger T.F., Gullberg G.T., Three-dimensional reconstruction in nuclear medicine emission imaging, IEEE Trans Nucl Sci, 21, pp. 2-20, (1974)
[7]  
Graham L.S., Niel R., In vivo quantitation of radioactivity using the Anger camera, Radiology, 112, pp. 441-442, (1974)
[8]  
Thomas S.R., Maxon H.R., Kereiakes J.G., In vivo quantitation of lesion radioactivity using external counting methods, Med Phys, 3, pp. 253-255, (1976)
[9]  
Ferrant A., Cauwe F., Quantitating organ-uptake measurement with a gamma camera, Eur J Nucl Med, 4, pp. 233-239, (1979)
[10]  
Fleming J.S., A technique for the absolute measurement of activity using a gamma camera and computer, Phys Med Biol, 24, pp. 176-180, (1979)