HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMN-SWITCHING TECHNIQUE FOR THE DETERMINATION OF INTERMEDIATES OF ANAEROBIC DEGRADATION OF TOLUENE IN GROUND-WATER MICROCOSM

被引:6
作者
CHAMKASEM, N
HILL, KD
SEWELL, GW
机构
[1] NSI TECHNOL SERV,ADA,OK 74820
[2] US EPA,RS KERR ENVIRONM RES LAB,ADA,OK 74820
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 587卷 / 02期
关键词
D O I
10.1016/0021-9673(91)85155-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reversed-phase liquid chromatographic column-switching system was used for the determination of phenol, benzoic acid and cresol (PBC) in the presence of toluene in ground water microcosm. A precolumn was connected in series with an analytical column via a column-switching valve. After the injection, as soon as PBC were eluted from the precolumn to the analytical column, the valve was switched so that the precolumn was between the analytical column and the UV detector. Toluene and other non-polar compounds were eluted from the precolumn in a very short time and detected along with the solvent front. Subsequently, PBC were separated on the analytical column and passed through the precolumn one more time before being detected by the UV detector. The total analysis time was 15 min. This technique facilitated the study of the basic mechanism and path way of anaerobic degradation of toluene in ground water aquifer.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 13 条
  • [1] AUTOMATED LIQUID-CHROMATOGRAPHIC ANALYSIS OF DRUGS IN URINE BY ONLINE SAMPLE CLEANUP AND ISOCRATIC MULTICOLUMN SEPARATION
    BINDER, SR
    REGALIA, M
    BIAGGIMCEACHERN, M
    MAZHAR, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 473 (02): : 325 - 341
  • [2] CHARACTERIZATION OF ANAEROBIC DECHLORINATING CONSORTIA DERIVED FROM AQUATIC SEDIMENTS
    GENTHNER, BRS
    PRICE, WA
    PRITCHARD, PH
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1989, 55 (06) : 1472 - 1476
  • [3] GRBICGALIC D, 1987, APPL ENVIRON MICROB, V53, P254
  • [4] COLUMN SWITCHING IN HIGH-PRESSURE LIQUID CHROMATOGRAPHY
    HUBER, JFK
    VANDERLI.R
    ECKER, E
    OREANS, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1973, 83 (AUG29): : 267 - 277
  • [5] LEACH LL, 1988, 2ND P NAT OUTD ACT C, V1
  • [6] INCREASED SAMPLE THROUGHPUT IN HPLC USING SAMPLE SWITCHING
    LITTLE, CJ
    STAHEL, O
    [J]. CHROMATOGRAPHIA, 1984, 19 : 322 - 326
  • [7] Lovely D.R., 1990, APPL ENVIRON MICROB, V56, P1858
  • [8] ROCKLIN RD, 1989, J CHROMATOGR SCI, V27, P4
  • [9] Snyder L.R., 1980, HIGH PERFORMANCE LIQ, V1, P207
  • [10] VEALS JW, 1988, AM LAB, V20, P42