DETERIORATION IN THE ACCURACY OF THE PULSAIR NONCONTACT TONOMETER WITH USE - NEED FOR REGULAR CALIBRATION

被引:17
作者
ATKINSON, PL
WISHART, PK
JAMES, JN
VERNON, SA
REID, F
机构
[1] ST PAULS EYE HOSP,GLAUCOMA UNIT,OLD HALL ST,LIVERPOOL L3,ENGLAND
[2] QUEENS MED CTR,DEPT OPHTHALMOL,NOTTINGHAM NG7 2UH,ENGLAND
[3] UNIV LONDON KINGS COLL,SCH MED & DENT,DEPT PUBL HLTH & EPIDEMIOL,LONDON WC2R 2LS,ENGLAND
关键词
PULSAIR NONCONTACT TONOMETER; GOLDMANN APPLANATION TONOMETER; SCREENING; GLAUCOMA; INTRAOCULAR PRESSURE;
D O I
10.1038/eye.1992.112
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The Pulsair non-contact tonometer (Keeler Pulsair(TM): Keeler UK) has been shown to be a versatile instrument particularly suitable for screening for raised intraocular pressure. Although demonstrated to be accurate initially when compared to the Goldmann applanation tonometer no study has examined its long-term accuracy. Comparisons of three Pulsair tonometers with different degrees of usage with the Goldmann tonometer are described. Measurements were obtained from 64, 116, and 223 eyes in three separate comparative studies. Correlation coefficients of between 0.78 and 0.90 were obtained, the least used instrument being significantly more accurate than the two more extensively used instruments. Taking the Goldmann tonometer as the standard tonometer, and the aim to detect intraocular pressures of greater than 21 mmHg, sensitivities of 40%, 48%, and 85% for the three Pulsair tonometers respectively were shown. The Pulsair tonometer appears liable to a long-term drift in accuracy with use, and we suggest that provision is made for the regular re-calibration of the instrument.
引用
收藏
页码:530 / 534
页数:5
相关论文
共 9 条
[1]   EVALUATION OF THE TONO-PEN AND THE PULSAIR TONOMETERS [J].
ARMSTRONG, TA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (06) :716-720
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
CLIMENHAGA H, 1989, CAN J OPHTHALMOL, V24, P7
[4]   A NEW HAND-HELD AIR IMPULSE TONOMETER [J].
FISHER, JH ;
WATSON, PG ;
SPAETH, G .
EYE, 1988, 2 :238-242
[5]   COMPARISON OF A NEW NON-CONTACT TONOMETER WITH GOLDMANN APPLANATION [J].
MOSELEY, MJ ;
EVANS, NM ;
FIELDER, AR .
EYE, 1989, 3 :332-337
[6]   NON-CONTACT TONOMETER - ITS VALUE AND LIMITATIONS [J].
SHIELDS, MB .
SURVEY OF OPHTHALMOLOGY, 1980, 24 (04) :211-219
[7]  
TUCK M, 1989, HLTH TRENDS, V21, P131
[8]   SCREENING FOR GLAUCOMA IN THE COMMUNITY BY NON-OPHTHALMOLOGICALLY TRAINED STAFF USING SEMI AUTOMATED EQUIPMENT [J].
VERNON, SA ;
HENRY, DJ ;
CATER, L ;
JONES, SJ .
EYE, 1990, 4 :89-97
[9]   NON-CONTACT TONOMETRY IN THE POSTOPERATIVE EYE [J].
VERNON, SA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (04) :247-249