PRACTICAL TRADEOFFS BETWEEN NOISE, QUANTITATION, AND NUMBER OF ITERATIONS FOR MAXIMUM LIKELIHOOD-BASED RECONSTRUCTIONS

被引:73
作者
LIOW, JS [1 ]
STROTHER, SC [1 ]
机构
[1] VET ADM MED CTR,PET IMAGE SERV,MINNEAPOLIS,MN 55417
关键词
D O I
10.1109/42.108591
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Images reconstructed using a maximum likelihood-expectation maximization (ML)-based method with different reconstruction kernels and 1-200 iterations are compared to images reconstructed using filtered backprojection (FBP). ML-based reconstructions using a single pixel (SP) kernel with or without a sieve filter show no quantitative advantage over FBP except in the background where a reduction of noise is possible if the number of iterations is kept small (< 50). ML-based reconstructions using a Gaussian kernel with a multipixel full width-at-half-maximum (FWHM) and a large number of iterations (200) require a sieve filtering step to reduce the noise and contrast overshoot in the final images. These images have some small quantitative advantages over FBP depending on the structures being imaged. It is demonstrated that a feasibility stopping criterion controls the noise in a reconstructed image, but is insensitive to quantitation errors, and that the use of an appropriate overrelaxation parameter can accelerate the convergence of the ML-based method during the iterative process without quantitative instabilities.
引用
收藏
页码:563 / 571
页数:9
相关论文
共 20 条
[1]  
Andrews H, 1977, DIGITAL IMAGE RESTOR
[2]  
BYARS LT, COMMUNICATION
[3]   ITERATIVE IMAGE-RECONSTRUCTION FOR POSITRON EMISSION TOMOGRAPHY - A STUDY OF CONVERGENCE AND QUANTITATION PROBLEMS [J].
HOLTE, S ;
SCHMIDLIN, P ;
LINDEN, A ;
ROSENQVIST, G ;
ERIKSSON, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :629-635
[4]   POSITRON EMISSION TOMOGRAPHIC-IMAGES AND EXPECTATION MAXIMIZATION - A VLSI ARCHITECTURE FOR MULTIPLE ITERATIONS PER SECOND [J].
JONES, WF ;
BYARS, LG ;
CASEY, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :620-624
[5]   ANALYSIS OF EMISSION TOMOGRAPHIC SCAN DATA - LIMITATIONS IMPOSED BY RESOLUTION AND BACKGROUND [J].
KESSLER, RM ;
ELLIS, JR ;
EDEN, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (03) :514-522
[6]   A HARDWARE ARCHITECTURE USING FINITE-FIELD ARITHMETIC FOR COMPUTING MAXIMUM-LIKELIHOOD ESTIMATES IN EMISSION TOMOGRAPHY [J].
KLOTZ, HA ;
SNYDER, DL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :279-290
[7]  
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306
[8]   ACCELERATED ITERATIVE RECONSTRUCTION FOR POSITRON EMISSION TOMOGRAPHY BASED ON THE EM ALGORITHM FOR MAXIMUM-LIKELIHOOD-ESTIMATION [J].
LEWITT, RM ;
MUEHLLEHNER, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :16-22
[9]   FEASIBLE IMAGES AND PRACTICAL STOPPING RULES FOR ITERATIVE ALGORITHMS IN EMISSION TOMOGRAPHY [J].
LLACER, J ;
VEKLEROV, E .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (02) :186-193
[10]   TOWARDS A PRACTICAL IMPLEMENTATION OF THE MLE ALGORITHM FOR POSITRON EMISSION TOMOGRAPHY [J].
LLACER, J ;
ANDREAE, S ;
VEKLEROV, E ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :468-477