ULTRASONOGRAPHIC ESTIMATION OF FETAL BODY-COMPOSITION FOR CHILDREN OF DIABETIC MOTHERS

被引:34
作者
BERNSTEIN, IM [1 ]
CATALANO, PM [1 ]
机构
[1] UNIV VERMONT,COLL MED,DEPT OBSTET & GYNECOL,BURLINGTON,VT 05405
关键词
BODY COMPOSITION; DIABETIC PREGNANCY; FETUS; MACROSOMIA; ULTRASOUND;
D O I
10.1097/00004424-199108000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors hypothesized that ultrasound-generated measurements of the fetus could be used to predict body composition for children of diabetic mothers. Seven ultrasonically identifiable fetal morphometric parameters were measured on 21 fetuses of diabetic mothers within 7 days of delivery. These seven individual measurements were then matched to neonatal morphometric estimations of body composition by means of stepwise regression analysis. Ultrasound variables which were found to show significant correlation to the newborn estimates of body composition were combined to generate an equation that could predict neonatal lean body mass and fat mass. Neonatal lean body mass could be predicted with R = .93 (P < .001, 95% confidence limits .80-.98). Neonatal fat mass could be predicted with R = .81 (P < .001, 95% confidence limits .55-.92). Prospective evaluation of the regression equations in an additional 18 patients showed no significant difference between ultrasound-predicted body composition and newborn morphometric estimation of body composition. The authors conclude that estimations of fetal body composition are possible, and may provide a valuable tool in the identification of fetal growth abnormalities.
引用
收藏
页码:722 / 726
页数:5
相关论文
共 18 条
  • [1] BRANS YW, 1989, BODY COMPOSITION MEA, P30
  • [2] CAMPBELL S, 1971, LANCET, V2, P1002
  • [3] ASSESSMENT OF TOTAL-BODY FAT IN INFANCY FROM SKINFOLD THICKNESS MEASUREMENTS
    DAUNCEY, MJ
    GANDY, G
    GAIRDNER, D
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1977, 52 (03) : 223 - 227
  • [4] BODY COMPOSITION OF INFANTS OF DIABETIC MOTHERS BY DIRECT ANALYSIS
    FEE, BA
    WEIL, WB
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1963, 110 (02) : 869 - &
  • [5] CEREBELLAR MEASUREMENTS WITH ULTRASONOGRAPHY IN THE EVALUATION OF FETAL GROWTH AND DEVELOPMENT
    GOLDSTEIN, I
    REECE, EA
    PILU, G
    BOVICELLI, L
    HOBBINS, JC
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 156 (05) : 1065 - 1069
  • [6] HILL DE, 1971, BIOL NEONATE, V19, P68, DOI 10.1159/000240403
  • [7] BODY COMPOSITION IN EXPERIMENTAL INTRAUTERINE GROWTH RETARDATION IN RAT
    HOHENAUER, L
    OH, W
    [J]. JOURNAL OF NUTRITION, 1969, 99 (1P1) : 23 - +
  • [8] OSLER M, 1960, ACTA ENDOCRINOL-COP, V34, P277
  • [9] MEASUREMENT OF TOTAL-BODY ELECTRICAL-CONDUCTIVITY - A NEW METHOD FOR ESTIMATION OF BODY-COMPOSITION
    PRESTA, E
    WANG, J
    HARRISON, GG
    BJORNTORP, P
    HARKER, WH
    VANITALLIE, TB
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1983, 37 (05) : 735 - 739
  • [10] TOTAL-BODY WATER MEASUREMENT IN HUMANS WITH O-18 AND H-2 LABELED WATER
    SCHOELLER, DA
    VANSANTEN, E
    PETERSON, DW
    DIETZ, W
    JASPAN, J
    KLEIN, PD
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1980, 33 (12) : 2686 - 2693