THE INFLUENCE OF VOLUME ON THE TOLERANCE OF THE BRAIN TO RADIOSURGERY

被引:104
作者
MARKS, LB
SPENCER, DP
机构
[1] Duke University Medical Center, Box 3085, Durham
关键词
RADIOSURGERY; BRAIN VOLUME; TOLERANCE; RADIATION;
D O I
10.3171/jns.1991.75.2.0177
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Radiosurgery (delivery of a high dose of radiation to a small volume of the brain) is usually well tolerated since the volume of brain irradiated is small. Despite growing interest in radiosurgery, the influence of the volume of brain irradiated on the tolerance of the brain to radiation is not well understood. The results of six studies reporting clinically significant radiation reactions following radiosurgery for arteriovenous malformations are reviewed. In the combined series, 23 (9%) of 255 patients developed a clinically significant radiation reaction. The volume of brain irradiated and the dose delivered in each of these 23 patients are presented. The compiled data suggest that the previously presented guidelines may underestimate the risks of radiosurgery. Additional clinical and experimental data are needed to determine "safe" doses of radiation to be used during radiosurgery.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 16 条
[1]   RELATION BETWEEN FIELD SIZE AND TOLERANCE OF RABBITS BRAIN TO ROENTGEN IRRADIATION (200 KV) VIA A SLIT-SHAPED FIELD [J].
BERG, NO ;
LINDGREN, M .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1963, 1 (03) :147-&
[2]   RADIATION MYELITIS OF THE CERVICAL SPINAL CORD [J].
BODEN, G .
BRITISH JOURNAL OF RADIOLOGY, 1948, 21 (249) :464-469
[3]   LINEAR-ACCELERATOR RADIOSURGERY OF CEREBRAL ARTERIOVENOUS-MALFORMATIONS [J].
COLOMBO, F ;
BENEDETTI, A ;
POZZA, F ;
MARCHETTI, C ;
CHIEREGO, G .
NEUROSURGERY, 1989, 24 (06) :833-840
[4]   ESTIMATION OF COMPLICATIONS FOR LINEAR-ACCELERATOR RADIOSURGERY WITH THE INTEGRATED LOGISTIC FORMULA [J].
FLICKINGER, JC ;
SCHELL, MC ;
LARSON, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (01) :143-148
[5]  
HINDO WA, 1970, CANCER-AM CANCER SOC, V26, P138, DOI 10.1002/1097-0142(197007)26:1<138::AID-CNCR2820260117>3.0.CO
[6]  
2-5
[7]   BRAGG-PEAK PROTON-BEAM THERAPY FOR ARTERIOVENOUS-MALFORMATIONS OF THE BRAIN [J].
KJELLBERG, RN ;
HANAMURA, T ;
DAVIS, KR ;
LYONS, SL ;
ADAMS, RD .
NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (05) :269-274
[8]  
Kjellberg RN, 1979, STEREOTACTIC CEREBRA, P157
[9]  
KJELLBERG RN, 1988, MODERN STEREOTACTIC, P463
[10]   STEREOTACTIC RADIOSURGERY FOR INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS USING A STANDARD LINEAR-ACCELERATOR [J].
LOEFFLER, JS ;
ALEXANDER, E ;
SIDDON, RL ;
SAUNDERS, WM ;
COLEMAN, CN ;
WINSTON, KR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (03) :673-677