PERFORMANCE ON TEST BEAM OF THE L3 DOUBLE-SIDED SILICON MICROSTRIP DETECTOR

被引:4
作者
ADAM, A
ADRIANI, O
AHLEN, S
AMBROSI, G
BABUCCI, E
BASCHIROTTO, A
BATTISTON, R
BY, A
BENCZE, GL
BERTUCCI, B
BIASINI, M
BILEI, GM
BOBBINK, GJ
BOSETTI, M
BROOKS, ML
BUSENITZ, J
BURGER, WJ
CAMPS, C
CARIA, M
CASTELLINI, G
CHECCUCCI, B
CHEN, A
COAN, TE
COMMICHAU, V
DIBITONTO, D
DUINKER, P
EASO, S
EXTERMANN, P
FIANDRINI, E
GOUGAS, A
HANGARTER, K
HAUVILLER, C
HERVE, A
HU, G
JOSA, I
KAPUSTINSKI, JS
KIM, D
KINNISON, WW
KRASTEV, VR
LANDI, G
LEBEAU, M
LECOMTE, P
LEE, DM
LEISTE, R
LIN, WT
LOHMANN, W
MARIN, A
MASSETTI, R
MILLS, GB
NOWAK, H
机构
[1] UNIV PERUGIA,INFN,I-06100 PERUGIA,ITALY
[2] RHEIN WESTFAL TH AACHEN,INST PHYS 3,W-5100 AACHEN,GERMANY
[3] UNIV ALABAMA,TUSCALOOSA,AL 35401
[4] BOSTON UNIV,BOSTON,MA 02215
[5] UNIV FLORENCE,INFN,I-50121 FLORENCE,ITALY
[6] IROE,INFN,FLORENCE,ITALY
[7] SWISS FED INST TECHNOL,CH-8006 ZURICH,SWITZERLAND
[8] UNIV GENEVA,CH-1211 GENEVA 4,SWITZERLAND
[9] NIKHEF,AMSTERDAM,NETHERLANDS
[10] UNIV MILAN,INFN,I-20122 MILAN,ITALY
[11] NCU,CHUNGLI,TAIWAN
[12] DESY,ZEUTHEN,GERMANY
[13] NATL TSING HUA UNIV,HSINCHU 300,TAIWAN
[14] TECH UNIV BUDAPEST,INST PHYS,H-1521 BUDAPEST,HUNGARY
[15] CERN,CH-1211 GENEVA 23,SWITZERLAND
[16] UNIV LAUSANNE,CH-1000 LAUSANNE 17,SWITZERLAND
[17] JOHNS HOPKINS UNIV,BALTIMORE,MD 21218
[18] RMKI,BUDAPEST,HUNGARY
关键词
Amplifiers (electronic) - Ion implantation - Microstrip devices - Particle beams - Readout systems - Signal to noise ratio - VLSI circuits;
D O I
10.1016/0168-9002(94)90775-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two modules of the L3 Silicon Microvertex Detector (SMD) have been tested on beam. The active area of the modules consists of double sided silicon microstrip detectors; the implantation pitch is 25 mum and 50 mum in the junction and ohmic side, respectively. The detectors are read out by a VLSI radiation hard amplifier (SVX-H). The position resolution, with a readout pitch of 50 mum and 200 mum for the two sides, is determined to be 7.0 mum and 14.3 mum. A signal to noise ratio greater-than-or-equal-to 16 and a detection efficiency greater-than-or-equal-to 99% are measured for both sides.
引用
收藏
页码:436 / 439
页数:4
相关论文
共 10 条
[1]  
ADRIANI O, 1993, NUCL PHYS B S, V32, P480
[2]  
ADRIANI O, 1994, 3RD LOND C POS SENS, V348, P431
[3]  
AMBROSI G, 1993, 3RD LOND C POS SENS
[4]  
BAGLIESI, 1988, NUCL INSTRUM METH A, V277, P147
[5]  
BERTUCCI B, 1993, 5TH TOP SEM EXPT APP
[6]  
COMMICHAU V, 1992, USERS MANUAL DRP
[7]  
DIBITONTO D, UNPUB NUCL INSTR MET
[8]  
MASSETTI R, 1993, THESIS U PERUGIA ITA
[9]  
TONISCH F, 1993, DESY IFH ZEUTHEN
[10]  
WEGMANN J, 1993, THESIS U JENA