摘要
Bleaching effluents from pulp and paper industry are problematic because they contain toxic chlorinated phenolic compounds and recalcitrant chlorinated lignin fragments of higher molecular weight. The chlorinated phenolic compounds have been shown to be rather easily removable in fluidized bed bioreactors. The total amount of adsorbable organic halogens (AOX), however, was only reduced by 20%-30%. It is generally possible to oxidize all unsaturated organic compounds in the bleaching effluents by ozonation. However, ozone is still too expensive to allow complete treatment. Nevertheless, the increase of biodegradability of recalcitrant components by dechlorination and degradation of high molecular weight fractions by ozone can lead to increased efficiency in a subsequent biotreatment. In this study the simple ozonation of bleaching effluents with and without biological pretreatment was compared with sequential or cyclic ozonation-biotreatment schemes. By integrated ozonation-biotreatment, the degradation efficiency relative to the amount of ozone consumed was markedly increased. The overall efficiency of the treatment process in terms of fractional removals of global parameters COD, TOC, and AOX increased. More than 70% of AOX were eliminated. No toxic effect was observed in the cyclic reactor, where the liquid passed was cycling between an ozonation and a biotreatment zone. In the liquid phase no dissolved ozone could be detected in this reactor.
引用
收藏
页码:67 / 77
页数:11
相关论文
共 41 条
[1]   OZONATION OF ORTHO-CRESOL IN AQUEOUS-SOLUTIONS [J].
BELTRAN, FJ ;
ENCINAR, JM ;
GARCIAARAYA, JF .
WATER RESEARCH, 1990, 24 (11) :1309-1316
[2]  
BOLLYKY LJ, 1989, OZONE WASTEWATER TRE, V2
[3]   MEMBRANE FILTRATION COMBINED WITH BIOLOGICAL TREATMENT FOR PURIFICATION OF BLEACH PLANT EFFLUENTS [J].
BOMAN, B ;
EK, M ;
HEYMAN, W ;
FROSTELL, B .
WATER SCIENCE AND TECHNOLOGY, 1991, 24 (3-4) :219-228
[4]   MICROBIAL-DEGRADATION OF CHLOROLIGNINS [J].
ERIKSSON, KE ;
KOLAR, MC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1985, 19 (11) :1086-1089
[5]   TREATMENT OF BLEACHING EFFLUENTS IN AEROBIC ANAEROBIC FLUIDIZED BIOFILM SYSTEMS [J].
FAHMY, M ;
HEINZLE, E ;
KUT, OM .
WATER SCIENCE AND TECHNOLOGY, 1991, 24 (3-4) :179-187
[6]  
FAHMY M, 1991, INT S ENV BIOTECHNOL, V4, P95
[7]   BIODEGRADABILITY OF OZONATION PRODUCTS AS A FUNCTION OF COD AND DOC ELIMINATION BY EXAMPLE OF SUBSTITUTED AROMATIC SUBSTANCES [J].
GILBERT, E .
WATER RESEARCH, 1987, 21 (10) :1273-1278
[8]  
GILBERT E, 1974, VOM WASSER, V43, P275
[9]  
GOULD JP, 1987, OZONE-SCI ENG, V9, P207
[10]  
HOIGNE J, 1983, WATER RES, V17, P185, DOI 10.1016/0043-1354(83)90099-4