AMPEROMETRIC BIOSENSORS FOR ONLINE MONITORING OF EXTRACELLULAR GLUCOSE AND GLUTAMATE IN THE BRAIN

被引:42
作者
ZILKHA, E [1 ]
KOSHY, A [1 ]
OBRENOVITCH, TP [1 ]
BENNETTO, HP [1 ]
SYMON, L [1 ]
机构
[1] KINGS COLL,BIOELECTROCHEM & BIOSENSORS GRP,LONDON W8 7AH,ENGLAND
关键词
BIOSENSOR; GLUTAMATE OXIDASE; GLUCOSE OXIDASE; INTERFERENCE; MICRODIALYSIS;
D O I
10.1080/00032719408001087
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two designs of thin film amperometric enzyme biosensor flow cell are described for the on-line measurement of glucose and glutamate concentrations in the extracellular fluid of the brain in conjunction with a microdialysis probe. The biosensors have high sensitivity and speed of response, enabling them to be used in the investigation of short term phenomena. The effects of oxidisable chemical compounds and other interferences on the amperometric current are discussed and strategies for eliminating these effects are described. Whereas the interferences can be adequately overcome with ease for glucose measurements in the millimolar range using platinised carbon paper-based enzyme electrodes, they are much more serious in the case of glutamate, which is present in brain extracellular fluid at much lower concentrations. Results are presented to demonstrate the applicability of two types of biosensor module for in vivo measurements.
引用
收藏
页码:453 / 473
页数:21
相关论文
共 11 条
[1]  
ANDERTON DJ, 1988, INT IND BIOTECHNOL, V8, P5
[2]  
BENNETTO HP, 1990, 1ST WORLD C BIOS, pP231
[3]   BRAIN MICRODIALYSIS [J].
BENVENISTE, H .
JOURNAL OF NEUROCHEMISTRY, 1989, 52 (06) :1667-1679
[4]   CONTINUOUS ASSAY OF NEURAMINIDASE ACTIVITY BY A BIENZYME SYSTEM IMMOBILIZED IN AN ARTIFICIAL MEMBRANE [J].
KOLISIS, FN ;
THOMAS, D .
BIOTECHNOLOGY AND BIOENGINEERING, 1987, 30 (02) :160-163
[5]  
KOSHY A, 1991, MONITORING MOLECULES IN NEUROSCIENCE, P128
[6]  
KOSHY A, 1993, ANALYT LETT, V26
[7]   EXTRACELLULAR LACTIC-ACID AS AN INDICATOR OF BRAIN METABOLISM - CONTINUOUS ONLINE MEASUREMENT IN CONSCIOUS, FREELY MOVING RATS WITH INTRASTRIATAL DIALYSIS [J].
KUHR, WG ;
KORF, J .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (01) :130-137
[8]   NITRIC-OXIDE MEASURED BY A PORPHYRINIC MICROSENSOR IN RAT-BRAIN AFTER TRANSIENT MIDDLE CEREBRAL-ARTERY OCCLUSION [J].
MALINSKI, T ;
BAILEY, F ;
ZHANG, ZG ;
CHOPP, M .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (03) :355-358
[9]   ELECTROPOLYMERIZED 1,2-DIAMINOBENZENE AS A MEANS TO PREVENT INTERFERENCES AND FOULING AND TO STABILIZE IMMOBILIZED ENZYME IN ELECTROCHEMICAL BIOSENSORS [J].
SASSO, SV ;
PIERCE, RJ ;
WALLA, R ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1111-1117
[10]   AMPEROMETRIC ENZYME ELECTRODES FOR THE DETERMINATION OF L-GLUTAMATE [J].
VILLARTA, RL ;
CUNNINGHAM, DD ;
GUILBAULT, GG .
TALANTA, 1991, 38 (01) :49-55