VELOCITY-MEASUREMENT OF COMPRESSIBLE AIR-FLOWS UTILIZING A HIGH-SPEED VIDEO CAMERA

被引:8
作者
RAFFEL, M
KOMPENHANS, J
STASICKI, B
BRETTHAUER, B
MEIER, GEA
机构
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 [机械工程];
摘要
PIV-measurements of the flow above a pitching airfoil were conducted in a transonic wind tunnel. An ultra high-speed video camera was used for separate recording of two exposures. The data was analysed using the cross-correlation method. The results show the applicability of the technique in high speed flows.